3
QUICK SPECIFICATIONS
COOLING & ELECTRIC HEAT
MODEL NUMBER
Cooling
Capacity
(BTUH)
EER
Electrical
Heating Ca-
pacity
(BTUH)
Reverse
Cycle Heat
(BTUH)
COP
Voltage
Range
Indoor CFM COOLING Approx.
Ship
Weight lb.
Low Med High AMPS WATTS
5 2 M E --- U 0 7 --- --- --- 3 --- ---
Determined
by your power
cord selection.
See chart be-
low.
--- ---
187 --- 253
--- --- --- --- --- ---
5 2 M E --- U 0 9 --- --- --- 3 8800 / 9000 11.4 / 11.4 --- --- 265 290 330 3.9 / 3.7 770 / 790 125
5 2 M E --- U 1 2 --- --- --- 3 12,000 / 12,100 11.4 / 11.5 --- --- 280 300 320 5/ 4.7 1060 / 1070 140
5 2 M E --- U 1 5 --- --- --- 3 --- --- --- --- --- --- --- --- --- ---
5 2 M E --- U 0 7 --- --- --- 4 --- --- --- ---
239---292
--- --- --- --- --- ---
5 2 M E --- U 0 9 --- --- --- 4 9,100 11.7 --- --- 265 300 320 3.3 790 125
5 2 M E --- U 1 2 --- --- --- 4 12,100 11.5 --- --- 280 310 345 4.35 1050 140
5 2 M E --- U 1 5 --- --- --- 4 --- --- --- --- --- --- --- --- --- ---
HEAT PUMPS
Model No.
Cooling
Capacity
(BTUH)
EER
Electrical
Heating Capa-
city (BTUH)
Reverse Cycle
Heat (BTUH)
COP
Voltage
Range
Indoor CFM COOLING
Approx. Ship
Weight lb.
Low Med High AMPS WATTS
5 2 M Q --- U 0 7 --- --- --- 3 --- ---
Determined by
your power
cord selection.
See chart be-
low.
--- --- --- --- --- --- --- --- ---
5 2 M Q --- U 0 9 --- --- --- 3 8,800 / 9,000 10.5 / 10.5 8,300 / 8,350 3.4 / 3.3 187 ---253 270 320 350 4.1 / 3.9 840 860 125
5 2 M Q --- U 1 2 --- --- --- 3 12,000 / 12,000 11.1 / 11.1 10,700 / 10,900 3.4 / 3.3 187---253 280 320 350 5.1 / 4.8 1080 1090 140
5 2 M Q --- U 1 5 --- --- --- 3 --- --- --- --- --- --- --- --- --- --- ---
5 2 M Q --- U 0 7 --- --- --- 4 --- --- --- --- --- --- --- --- --- --- ---
5 2 M Q --- U 0 9 --- --- --- 4 9,000 10.9 8,400 3.5 239---292 275 285 300 3.2 825 125
5 2 M Q --- U 1 2 --- --- --- 4 11,400 10.8 10,600 3 239---292 220 250 290 4.2 1,050 140
5 2 M Q --- U 1 5 --- --- --- 4 15,000 --- --- --- --- --- --- --- --- --- ---
POWER CORD SELECTION:
52M PTACs are not individually equipped with a power cord, so one must be ordered separately based on the voltage and amperage of your electrical circuit. If the
unit i s t o be plugged into a recept acle, then a l ine cord connecti on ki t needs to be sel ect ed. If i t will be permanentl y connect ed, a hardwire connection must be used.
Model No. Voltage Receptacle Type
Heating
(BTUH)
Heater (Kw)
Input Power
(Watts)
Current
(Amps)
Branch Circuit
Full Amps
PWRCORD--- 230V --- 15A
208/230V
15 amp /250V 7,800 / 6,400 2.5 2,393 / 1,985 10.4 / 9.5 15
PWRCORD--- 230V --- 20A 20 AMP / 250V 11,600 / 9,700 3.4 3,493 / 2,935 11.52 / 14.1 20
PWRCORD--- 230V --- 30A 30 AMP / 250V 17,000 / 13,600 5.0 5,170 / 4,147 22.5 / 20.0 30
PWRCORD--- 265V --- 15A
265V
15 AMP / 277V 7,800 2.5 2,396 9.2 15
PWRCORD--- 265V --- 20A 20 AMP / 277V 11,600 3.4 3,496 13.3 20
PWRCORD--- 265V --- 20A 30 AMP / 277V 17,000 5.0 5,170 19.6 30
NOTE: In compliance with UL, and the National Electrical Code, 265V units installed iwth a power cord require the u se use of a 265V electrical subbase.
Always look for these symbols, the air conditioning
industr
seals of certified
erformance, efficienc
and ca
acit
.
52M