5
669224-R5
NSTALLATION
I
3
Prepare hoses
CAUTION: Connect the hydraulic hoses to the attachment
using Cascade Attachment Installation Kit No. 659245
for non-sideshifting attachments and attachments with
solenoid adaption, Kit No. 659249 for sideshifting clamps
OR use hoses and fittings as shown.
A Position the truck carriage behind the attachment to
determine hose lengths required for hydraulic supply
configuration.
B Cut hoses to length and install end fittings or use hose
kits supplied.
WARNING: Do not remove the
fitting from the valve CLAMP (CL)
port. For No. 6 hose connection,
use a 6-8 reducer.
CL0448.ai
Sideshift Right – De-energized
Close – Energized
Sideshift Right – De-energized
Close – Energized
Sideshift Right – De-energized
Close – Energized
Sideshift Left – De-energized
Open – Energized
Sideshift Left – De-energized
Open – Energized
Sideshift Left – De-energized
Open – Energized
CL0444.ai
CL0447.eps
Hoses should not project
above the Check Valve
Bracket
No. 8 Hoses
(SAE 100 R5 Single
Wire Braid Rubber
Covered)
Remove fittings
and cut hoses
to length
No. 6 Hoses
(SAE 100 R5 Single Wire
Braid Rubber Covered)
(Sideshifting attachments only)
Top Mount Valve
Center Mount Valve
Top Mounted Valve and
Backrest Mounted Solenoid Adaption
Center Mount Valve
and Solenoid Adaption
Top Mounted Valve
and Solenoid Adaption
CL0911.ai
CL0910.ai
Sideshift Right/Left
(These hoses apply to
sideshifting attachments only)
No. 8 Hoses
(SAE 100 R5 Single Wire
Braid Rubber Covered)
Close/Open