CO
When the ENV key
of the
DCO
1
or DCO
2 is
pressed,
the following
appears on the LCD.
StiS will be
displayed
if the displayed
STEP
is a
sustain
point.
END
will be displayed
if
it is an end point.
Pitch
envelope
STEP 1 selected.
PITCH STEP!
+++
RfiTE=".«<
LEUEL=".«
/ 00gmimj^99
''
VOOsnim
£99
1
Rale of step
1
Destination level
of step
1,
<D
Use the
®
VALUE
key to raise
the RATE
value
to
99.
CD
Use either one
of
the CURSOR
keys
to
move
the
cursor under the
LEVEL value.
Use the
H
VALUE
key to raise
the
LEVEL
value to
99, This
completes the
setting
of STEP
1.
©Use the ENV STEP
S
key
to advance
to
STEP
2. After
ensuring the STEP 2
is
displayed, follow the
same procedures
outlined for
STEP 1 to set the
RATE
to
72 and the
LEVEL
to 66.
®
Press the ENV
POINT
SUSTAIN key
to
designate
STEP 2
as a SUSTAIN
POINT.
(D
Use the ENV
STEP
®
key to advance
to STEP 3 and set the
RATE
to 60 and
the
LEVEL
to 24.
(J)
Use
the
ENV STEP
B
key to
advance
to STEP
4 and set
the RATE
to 20. Then
press the ENV
POINT
END key
to set
the END
POINT,
and the LEVEL
will
au-
tomatically
be
set
to 00.
*lt is
not necessary to
press
the END key
PITCH
STEPi
***
RFlTE-99
LEUELj—
PITCH STEPI
***
RflTE=99
LEUEL=99
PITCH STEP2
***
RflTE=72
LEUEL=66
SUSTAIN POINT
*Mi
Ml 'll
PITCH
STEP2
RflTE=72 LEUEL=66
PITCH
STEP3
***
RflTE=60
LEUEL=23
END POINT
PITCH
STEP4
END
RflTE=20 LEUEL=@@
LEVEL of the last step is 00.
if
the END POINT
is already set.
RATE/LEVEL
NUMERIC
VALUES
RATE
The RATE
indicates
the
slope
(interior angle
in relation
to horizontal)
of each step
in the envelope. R
-
99 indi-
cates nearly
90°
while
R
=
indicates
nearly
0°.
Since
the value used
is an absolute
value, the slope increases
and
decreases in direct
proportion
with the value of R,
regardless of whether
the pattern
shows a rise or fall.
This means
that
a
steep
incline results
In
a quick level
change
while a gentle incline
results in
a slow level
change.
LEVEL
The LEVEL indicates up
to
what
point
each step
rises
or falls (destination level),
and
the range is from
00
through
99, For the DCO
envelope, LEVEL
means the
pilch
height, cind
a
value
of 00 is (hi: pilch
of
•:
pressed
key.
For the DCW envelope,
L
=
99 results in
a
basic
waveform
{see page 20 for
details). For the
DCA enve-
lope,
LEVEL means
the
volume.
LEVEL
Pr*
=
99
AjWee
P:
=
6&
7IML
fl
fi
^99
PART 1 NORMAL MODE
17'

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Casio CZ-3000 and is the answer not in the manual?

Casio CZ-3000 Specifications

General IconGeneral
BrandCasio
ModelCZ-3000
CategorySynthesizer
LanguageEnglish

Related product manuals