DIAGNOSTIC CODE
Up Arrow Down Arrow
Flash(es) Flash(es)
51
55
61
SYMPTOM
Terminal 1+2 for wall control is short-
ened longer than 4 seconds
Low voltage
Maximum radio memory has been
reached.
SOLUTION
Check wiring for push button if button is stuck and activated permanently. Remove
wiring from terminal 1+2 on operator as test. Do not run push button wires next to high
voltage wiring or in same conduit.
The operator has been shut off due to lower voltage supplied than allowed.
If an external backup battery pack is installed, check if empty. If mains supply is used,
check wiring and supply.
Maximum capacity for storage of remote controls has been reached. The first remote
control or more previously programmed remote controls’ codes have been replaced by
a new one. To reset diagnostic remove power from the operator.
Optional Accessories
1. TX4RUNI - 4-channel remote control
2. 128REV - Wireless Wall Control 2-Channel
3. 747REV - Keypad
4. 830REV - myQ Starter Kit (Gateway + Photocells)
5. 829REV - Garage Door Monitor
6. 1REV - Quick release
7. 1702REV - Quick release
8. 75REV - Wired push button
9. FLA-1LED - Flashing light
10. 771REV - Photocells
11. 41REV - Key switch (surface mount)
12. 16200LM - Door in Door contact
34

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chamberlain ML700EV and is the answer not in the manual?

Chamberlain ML700EV Specifications

General IconGeneral
BrandChamberlain
ModelML700EV
CategoryGarage Door Opener
LanguageEnglish

Related product manuals