Site wiring is unlikely to emit radio interference if you use twisted-pair cable with good distribution of
grounding conductors. Use a high-quality twisted-pair cable with one ground conductor for each data signal,
when applicable.
Give special consideration to the effect of lightning strikes in your vicinity, especially if the wiring exceeds
recommended distances, or if it passes between buildings. The electromagnetic pulse (EMP) caused by lightning
or other high-energy phenomena can easily induce enough energy into unshielded conductors, and destroy
electronic devices. If you have experienced EMP problems in the past, you may want to consult experts in
electrical surge suppression and shielding.
Most data centers cannot resolve infrequent, but potentially catastrophic, problems without pulse meters and
other special equipment. In addition, these problems can take a great deal of time to identify and resolve. We
recommend that you take the necessary precautions to avoid these problems by providing a properly grounded
and shielded environment, with special attention to issues of electrical surge suppression.
Chassis Air Flow Guidelines
Cisco ASR 9901 Router
Cool air is circulated front-to-back through the Cisco ASR 9901 Router by three fan trays located in the rear
of the router (see the following figure).
The fan trays maintain acceptable operating temperatures for the internal components by drawing in cool air
through the vents, and circulating the air through the chassis. Each power supply is also equipped with fans
that draw cool air into the front of the power supply and force warm air out of the air exhaust.
See the following section for details on air flow clearance requirements for installation in an enclosed 4-post
rack.
Note
Preparing for Installation
9
Preparing for Installation
Chassis Air Flow Guidelines

Other manuals for Cisco ASR 9901

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASR 9901 and is the answer not in the manual?

Cisco ASR 9901 Specifications

General IconGeneral
Chassis Height1 RU
Rack MountingYes
RedundancyYes
Operating SystemCisco IOS XR
Switching CapacityUp to 1.2 Tbps
Memory16 GB
Power SupplyDual redundant AC or DC
Interfaces10GE, 100GE
Operating Temperature0 to 40°C (32 to 104°F)
Input Voltage100-240V AC
Power ConsumptionVaries based on configuration
Storage64 GB SSD
Humidity5% to 95% (non-condensing)

Related product manuals