Removing and Replacing Modules
This procedure describes how to remove and replace the internal modules of the node. All field-replaceable
modules can be removed and replaced without removing power from the node.
Field-replaceable modules include:
Forward optical receiver modules
Reverse optical transmitter modules
Status monitor/local control module
Forward configuration module
Reverse configuration module
Equalizers
Node signal directors
Power supply modules
RF amplifier assembly
RPD Module
Removing power from the node will interrupt customer service. Removing any module, except for the status
monitor/local control module, will interrupt customer service unless that module has a redundant backup.
Caution
Module Replacement Procedure
Follow this procedure to remove and replace an optical receiver, optical transmitter, optical amplifier, optical
switch, status monitor/local control module, or power supply module.
1. Open the housing. See Opening and Closing the Housing, on page 1.
2. Carefully tag and remove any optical fibers from RPD, receiver or transmitter module.
Laser light hazard. Never look into the end of an optical fiber or connector. Failure to observe this warning
can result in eye damage or blindness.
Warning
3. Loosen the screws securing the module.
4. Lift the module straight up out of the housing to unplug it.
Maintenance
5
Maintenance
Removing and Replacing Modules

Other manuals for Cisco GS7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco GS7000 and is the answer not in the manual?

Cisco GS7000 Specifications

General IconGeneral
BrandCisco
ModelGS7000
CategoryNetwork Hardware
LanguageEnglish

Related product manuals