EasyManuals Logo
Home>Clarion>Amplifier>XC7420

Clarion XC7420 User Manual

Clarion XC7420
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
10
ENGLISH
TROUBLESHOOTING - ERROR CODES
Clarion XC7 ampli ers use a microcontroller to manage the operation of the ampli er.
Included in the rmware is the ability to detect errors in the functionality of the ampli er.
The following error code chart can be used to look up the cause of a fault.
The following codes are shown by a red ashing pattern of the Power/Protect LED.
Code 1 - Indicates that the power connection voltage is too low. Check all your power
connections. This is most commonly caused by a poor ground connection.
Code 2 - There is an over-current condition on Channel 1-4. This could be caused by a
shorted speaker, a grounded speaker wire or an internal fault. Disconnect all speaker
wires and test again.
Code 3 - The ampli er has detected the occurrence of short circuits on the last three
power-up attempts. Correct this condition, remove power from the ampli er for 15 minutes
and try again.
Code 4 - Indicates that the battery connection voltage is too high. Check the functionality
of the vehicle charging system.
Code 5 - This error indicates that there is a DC voltage present on one of the speaker
leads. The ampli er will need to be serviced.
Code 6 - There is an over-current condition on Channel 5 of the XC7520. This could be
caused by a shorted speaker, a grounded speaker wire or an internal fault. Disconnect all
speaker wires and test again.
Heatsink Over Temperature - This error indicates that the chassis of the ampli er has
exceeded the recommended operating voltage. Review your choice of installation location,
ensuring that there is adequate air ow around the ampli er. Also check your wiring to
make sure the ampli er is getting enough voltage and has a good ground connection.
Power Supply Over-Temperature - This error indicates that the power supply of the
ampli er has exceeded the recommended operating voltage. Ensure that the ampli er is
getting adequate voltage.
Code 3 - Repeated Short Circuit
Code 4 - Power Supply Over Voltage
Code 1 - Power Supply Under Voltage
Code 2 - Channel 1-4 Short Circuit
Over Temperature - Heatsink
Over Temperature - Power Supply
Code 5 - DC Voltage Speaker Protection
Code 6 - Channel 5 Short Circuit
Turn-On Process
Turn-On Process (after reset)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Clarion XC7420 and is the answer not in the manual?

Clarion XC7420 Specifications

General IconGeneral
BrandClarion
ModelXC7420
CategoryAmplifier
LanguageEnglish

Related product manuals