EasyManuals Logo
Home>Clarke>Water Pump>CSV1A

Clarke CSV1A User Manual

Clarke CSV1A
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
4
ELECTRICAL CONNECTIONS
Connect the mains lead to a suitable 110 Volt (50Hz) electrical supply through
an approved plug or a suitably fused isolator switch, or to a suitable portable
110 volt transformer.
We recommend that this pump is fitted with a Residual Current Device (RCD).
If the pump is to be connected to an outdoor electrical supply, ensure both
the plug and the socket are of a British Standard approved waterproo
f design.
The wires in the mains lead are coloured according to with the following code:
Green & Yellow - Earth
Blue - Neutral
Brown - Live
As the colours of the flexible power cable of this appliance may not
correspond with the coloured markings identifying terminals in your plug
proceed as follows:
Connect GREEN & YELLOW wire to the terminal marked with a letter “E” or
Earth symbol ’or coloured GREEN or GREEN & YELLOW.
Connect BROWN wire to terminal marked with a letter “L” or coloured RED
Connect BLUE wire to terminal marked with “N” or coloured BLACK
IMPORTANT: If you are in any doubt regarding electrical installation, you should
consult a qualified electrician.
PUMP PERFORMANCE DATA
WARNING: THIS APPLIANCE MUST BE EARTHED

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Clarke CSV1A and is the answer not in the manual?

Clarke CSV1A Specifications

General IconGeneral
BrandClarke
ModelCSV1A
CategoryWater Pump
LanguageEnglish

Related product manuals