6. Delay between warning messages - User adjustable setting for the delay between the audible
alarms that occur during a power failure.
7. UPS Self-test - Allows the user to test the UPS without having to unplug the unit from the wall.
When the run button is clicked, the unit will switch to battery power and the unit will beep.
8. About - This button will display information about the software, as well as contact information.
9. Advance - This button opens the Advanced Setup Window.
10. Default - Click this button to return the software to the original factory settings.
11. Cancel - This button exits the window without saving changes.
12. OK - This button exits the windows and saves any changes.
13.
14. Buzzer - This toggles the audible alarm on and off.
UPS Installed On - Shows the port that the UPS is using. The port assigned to the UPS needs to
TM
be used exclusively by the PowerPanel Plus software.
TM
POWERPANEL PLUS ADVANCED SETUP
1. Low Battery Voltage - This sets the low
battery cutoff level. The user can slightly
extend the UPS run-time by adjusting this
setting.
2. High-Voltage Failure - Sets the upper
level where the UPS will cycle to battery.
3. Low-Voltage Failure - Sets the lower
level where the UPS will cycle to battery.
4. Battery-mode Output Voltage - Sets the
voltage that the UPS will output when
running on battery. This level can be
adjusted from 100v to 125v.
5. Cold Start - When enabled, the UPS can start in the absence of AC power. To maximize battery
life, it is recommended to keep this disabled.
6. Default - Restores settings to the factory defaults.
7. Cancel - Exits the window without saving changes.
8. OK - Exits the window and saves changes.
9. Remote On Function - This function is not available with this model.
8
TM
POWERPANEL PLUS SCHEDULE MENU
1. Special Setting - This setting allows you
to schedule a one-time shutdown/startup.
2. Schedule Display - This area displays
the days/dates/times of any scheduled
shutdown/startup.
3. Turn On - Select the day/date/time that
you want the system to start. Must be
scheduled in conjunction with a shutdown.
4. Turn On Disabled - When button states
“Turn On Disabled”, the UPS will restart
according to the schedule. When button
states “Turn On Enabled”, the UPS will not
restart according to the schedule.

Other manuals for CyberPower CPS1500AVR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CyberPower CPS1500AVR and is the answer not in the manual?

CyberPower CPS1500AVR Specifications

General IconGeneral
Output power950 W
Input frequency50/60 Hz
Audible alarm(s)Yes
Surge energy rating1.800 J
Output power capacity1.5 kVA
Weight (imperial)58 lbs
Dimensions (WxDxH)438.15 x 400 x 89 mm
Operating temperature (T-T)32 - 95 °F
Dimensions (W x D x H) (imperial)17.25 x 15.75 x 3.5 \
Battery technologySealed Lead Acid (VRLA)
Battery recharge time8 h
Typical backup time at full load6 min
Typical backup time at half load18 min
Modem (RJ-11) ports1
Serial ports quantity2
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
Operating relative humidity (H-H)0 - 95 %
CertificationUL1778, cUL, FCC DOC Class B