CAUTION! A battery can present a high risk of short circuit current an electrical shock. Take the
following precautions before replacing the battery:
1. Remove all watches, rings or other metal objects.
2. Only use tools with insulated handles.
3. DO NOT lay tools or other metal parts on top of battery or any battery terminals.
4. Wear rubber gloves and boots.
5. Determine if the battery is inadvertently grounded. If inadvertently grounded, remove
source of ground. CONTACT WITH A GROUNDED BATTERY CAN RESULT IN
ELECTRICAL SHOCK! The likelihood of such shock will be reduced if such grounds are
removed during installation and maintenance (applicable to a UPS and a remote battery
supply not having a grounded circuit).
TO REPLACE THE BATTERY
1. Remove the right-side of the faceplate.
2. Disconnect the black and red cable.
3. Remove the 4 retaining screws.
4. Pull battery pack from unit.
5. Slide the new battery pack into the unit.
6. Replace the 4 retaining screws.
7. Connect the black and red cable.
8. Replace the cover.
12
REPLACING THE BATTERY
CAUTION!
CAUTION!
CAUTION!
CAUTION!
Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery.
Service the battery under the supervision of personnel knowledgeable of batteries and their
precautions.
Use only the specified type of battery. See your dealer for replacement batteries.
The battery may present the risk of electrical shock. Do not dispose of batteries in a fire,
as it may explode. Follow all local ordinances regarding proper disposal of batteries.
Do not open or mutilate the batteries. Release electrolyte is harmful to the skin and eyes
and may be toxic.

Other manuals for CyberPower CPS1500AVR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CyberPower CPS1500AVR and is the answer not in the manual?

CyberPower CPS1500AVR Specifications

General IconGeneral
Output power950 W
Input frequency50/60 Hz
Audible alarm(s)Yes
Surge energy rating1.800 J
Output power capacity1.5 kVA
Weight (imperial)58 lbs
Dimensions (WxDxH)438.15 x 400 x 89 mm
Operating temperature (T-T)32 - 95 °F
Dimensions (W x D x H) (imperial)17.25 x 15.75 x 3.5 \
Battery technologySealed Lead Acid (VRLA)
Battery recharge time8 h
Typical backup time at full load6 min
Typical backup time at half load18 min
Modem (RJ-11) ports1
Serial ports quantity2
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
Operating relative humidity (H-H)0 - 95 %
CertificationUL1778, cUL, FCC DOC Class B