TORQUE FUNCTION
Shows the torque placed on the hub in inch-pounds. To display torque while
in trip mode:
1) Press [MODE] to scroll the cursor to the top line of the main display.
2) Press [SELECT] until the current power function is displayed.
3) Hold [SELECT] until the word WATTS” begins to flash. A blinking “WATTS” display indicates
the torque function is currently displayed.
4) Press [SELECT] to return to the current power function. (FIGUR
E 12).
3
D
000
25
58.I0
15
FIGURE 12
IMPORTANT: ZERO TORQUE
Frequently
the torque must be zeroed to ensure the most accurate power
information is displayed. If the current power display is positive or
negative while coasting the the torque must
be zeroed. This operation
must be done while stopped with no tension on the chain, no tension
placed on the pedals, and the transmission icon must be illuminated. To
zero torque:
1) Press [MODE] to scroll the cursor to the top line of the main display.
2) Press [SELECT] until current power function is displayed.
3) Hold [SELECT] until the word WATTS” begins to flash to enter the
torque function.
4) Hold [SELECT] again until “0” is shown.
5) Press [SELECT] to return to current power. The current power function
will now read zero while coasting.

Other manuals for CycleOps PowerTap SLC+

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CycleOps PowerTap SLC+ and is the answer not in the manual?

CycleOps PowerTap SLC+ Specifications

General IconGeneral
BrandCycleOps
ModelPowerTap SLC+
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals