EasyManuals Logo
Home>Daikin>Controller>Advanced plus

Daikin Advanced plus User Manual

Daikin Advanced plus
Go to English
192 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #35 background imageLoading...
Page #35 background image
Installation and operation manual
13
FWEC3
Advanced plus electr
onic controller
FC66002765
Mon:
- H30 = daily pr
o le (1 or 2) for MONDAY
Tue:
- H31 = daily pro le (1 or 2) for TUESDAY
Wed:
- H32 = daily pro le (1 or 2) for WEDNESDAY
Thu:
- H33 = daily pro le (1 or 2) for THURSDAY
Fri:
- H34 = daily pro le (1 or 2) for FRIDAY
Sat:
- H35 = daily pro le (1 or 2) for SATURDAY
Sun:
- H36 = daily pro le (1 or 2) for SUNDAY
- H37 = 24H or 12H display
DEFAULT VALUES OF PARAMETERS
- H00 = 0 (scheduling disabled)
- H01 = 06:00
- H02 = 22:00
- H03 = 08:00
- H04 = 20:00
- H12 = OFF
- H13 = ON
- H14 = OFF
- H15 = OFF
- H16 = ON
- H17 = OFF
- H18-H23 = 25°C
- H24-H29 = 22°C
- H30-H34 = 1
- H35-H36 = 2
- H37 = 24H
If the 12H display mode has been set (parameter H37), for
con guration parameters H01 to H11 (except H03) the display will
not show the sequential number of the parameter but rather
the hourly situation expressed in AM/PM.
DISPLAY
If the time programming function is enabled, when the ther-
mostat is on the clock symbol will always appear and it will be
possible to check whether the time settings are correct (only
for a few instants) by simultaneously pressing the SEL+MODE
buttons. When the thermostat is off, the clock symbol and
current hour will appear constantly on the display only if the
ON/OFF time programming mode is enabled.
PARAMETER LIST
Time schedules ar
e programmed by setting the individual pa-
rameters encountered when scrolling with the arrow keys.
Warning: there are a total of 37 parameters, but not of all them
are accessible. Whether certain parameters will be displayed
or not depends on the value assigned to the rst parameter
(H00), i.e. the operating mode selected. More speci cally:
if H00=(ON/OFF mode), parameters H18 to H29 will not be
displayed
if H00=2 (operation based on temperature SETPOINT),
parameters H12 to H17 will not be displayed
if H00=0 the time programming function is disabled and
therefore no parameter will be displayed except for H00
Below is a description of all 37 parameters, in sequence.
H00 ENABLING AND OPERATING MODES
- H00=0: scheduling disabled
- H00=1: ON/OFF time schedules
- H00=2: time schedules based on temperature SETPOINT
CLO:
- H01 = HOUR of controller clock
- H02 = MINUTES of controller clock
DAY:
- H03 = DAY OF THE WEEK
Hr1:
- H04 = OUR (0-23) of SCHEDULE 1
- H05 = MINUTES (0-59) of SCHEDULE 1
Hr2:
- H06 = HOUR (0-23) of SCHEDULE 2
- H07 = MINUTES (0-59) of SCHEDULE 2
Hr3:
- H08 = OUR (0-23) of SCHEDULE 3
- H09 = MINUTES (0-59) of SCHEDULE 3
Hr4:
- H10 = HOUR (0-23) of SCHEDULE 4
- H11 = MINUTES (0-59) of SCHEDULE 4
- H12 = STATUS (ON or OFF) of TIME SLOT 1
- H13 = STATUS (ON or OFF) of TIME SLOT 2
- H14 = STATUS (ON or OFF) of TIME SLOT 3
- H15 = STATUS (ON or OFF) of TIME SLOT 4
- H16 = STATUS (ON or OFF) of TIME SLOT 5
- H17 = STATUS (ON or OFF) of TIME SLOT 6
SP1:
- H18 = SUMMER temperature SETPOINT of TIME SLOT 1
SP2:
- H19 = SUMMER temperature SETPOINT of TIME SLOT 2
SP3:
- H20 = SUMMER temperature SETPOINT of TIME SLOT 3
SP4:
- H21 = SUMMER temperature SETPOINT of TIME SLOT 4
SP5:
- H22 = SUMMER temperature SETPOINT of TIME SLOT 5
SP6:
- H23 = SUMMER temperature SETPOINT of TIME SLOT 6
SP1:
- H24 = WINTER temperature SETPOINT of TIME SLOT 1
SP2:
- H25 = WINTER temperature SETPOINT of TIME SLOT 2
SP3:
- H26 = WINTER temperature SETPOINT of TIME SLOT 3
SP4:
- H27 = WINTER temperature SETPOINT of TIME SLOT 4
SP5:
- H28 = WINTER temperature SETPOINT of TIME SLOT 5
SP6:
- H29 = WINTER temperature SETPOINT of TIME SLOT 6