14 Configuration
Installer and user reference guide
16
BRC1H519W+K+S
Wired remote controller
4P513689-1A – 2018.03
Level Description
First level Mode (Mode)
A mode is a group of settable parameters.
In the field settings tables, find available mode numbers in the "Mode" column. Mode
numbers that apply to individual indoor units are between brackets in the "Mode"
column.
Unit (Unit) (indoor unit field settings only)
A unit is an individual unit to which a setting might apply.
When making field settings for individual units, this is the place where you define the
number of the unit to which the setting applies.
When making field settings for grouped units, you do NOT set the unit number. The
settings will then apply to all indoor units that are part of that group.
Second level Setting (SW)
A setting is a settable parameter. These are the settings you are making.
In the field settings tables, find the available setting numbers in the "SW" column.
Value
A value is one of a fixed set of values that you can choose for a setting.
When the value field contains a "-", there are no values available for the selected
setting:
SW 00
When making group settings, you can ONLY set a value for a setting if the value field
contains a "*" (if the value field does NOT contain a "*", you cannot apply the selected
setting to the group):
SW 00
In the field settings tables, find the available values for each setting in the "Value"
column.
Navigation
To navigate through the field settings menus, use , , and .
1 Use and to move the highlighter.