© Danfoss A/S (AC-MCI/MWA), 2012-05 DKRCI.PD.SC0.C3.02 / 520H5687 3
Liquid Level Sensor, AKS 4100/4100U
Product concept
Cable version
The cable version consists of:
 Signal converter, which can be supplied
with or without HMI
 Mechanical process connection with 5 m
(197 in.) ø2 mm (0.08 in.) stainless cable
 Counterweight
 Accessory bag comprising:
3 mm set screws
Red cover to protect mechanical process
connection prior to mounting signal
converter.
Setting label.
With the cable version it is possible to adapt the
AKS 4100/4100U to any possible length in the
range of 800 mm (31.5 in.) to 5000 mm (196.9 in.)
Danfoss
M84H0001_1
Danfoss
M84H0021_1
CABLE version: COAXIAL version:
AKS 4100/4100U is available
in two dierent versions:
Cable version
Coaxial version
Cable version
Both Cable and Coaxial versions are available with
two dierent mechanical process connections:
AKS 4100: G1 in. pipe thread.
Aluminium gasket included
AKS 4100U: ¾ in. NPT
AKS 4100/4100U cable version must
ALWAYS be installed in a standpipe.

Other manuals for Danfoss 084H4505

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss 084H4505 and is the answer not in the manual?

Danfoss 084H4505 Specifications

General IconGeneral
BrandDanfoss
Model084H4505
CategoryAccessories
LanguageEnglish

Related product manuals