This is the most energy and cost efficient way to set the indoor tempera-
ture and should therefore be used for long term temperature settings.
4
2 0 0 -2 0
2 4
4 0
5 6
2
3
1
5
1. Supply temperature (°C)
2. Maximum setpoint value°
3. Outdoor temperature (°C)
4. 0°C
5. °Set value (standard 40°C)
The following parameters can be adjusted:
Parameter Description
CURVE If the CURVE value is increased, the heat curve will become
steeper and if the value is reduced, it will become flatter. Raise
for hotter indoor temperature, reduce for lower temperature.
MIN Lowest set point for supply temperature.
MAX Highest set point for supply temperature.
CURVE 5 Used to adjust the heat curve at an outdoor temperature of
+5°C.
CURVE 0 Used to adjust the heat curve at an outdoor temperature of
0°C.
CURVE -5 Used to adjust the heat curve at an outdoor temperature of
-5°C
HEAT STOP This function stops all production of heat when the outdoor
temperature is equal to, or higher than, the set heat stop value.
Note! High temperatures in an underfloor heating system can
damage parquet floors.
User manual VUBMA902 – 17

Other manuals for Danfoss DHP-L Opti

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss DHP-L Opti and is the answer not in the manual?

Danfoss DHP-L Opti Specifications

General IconGeneral
BrandDanfoss
ModelDHP-L Opti
CategoryHeat Pump
LanguageEnglish

Related product manuals