Danfoss ECtemp Touch
Installation Guide4
Sensing values:
(Default NTC 15 K)
0°C
20°C
50°C
42 kΩ
18 kΩ
6 kΩ
Control PWM (Pulse Width Modulation)
Ambient temperature 0° to +30°C
Frost protection temperature 5°C to +9°C (default 5°C)
Temperature range Room temperature: 5-35°C.
Floor temperature: 5-45°C.
Max. oor: 20-35°C (if unrecov-
erable seal is broken then up to
45°C). Min. oor: 10-35°C, only
with combination of room and
oor sensor.
Sensor failure monitoring The thermostat has a built-in
monitoring circuit, which will
switch o the heating if the
sensor is disconnected or short-
circuited
Cable specication max. 1x4 mm
2
or 2x2,5 mm
2
Ball pressure test temperature 75°C
Pollution degree 2 (domestic use)
Controller type 1C
Software class A
Storage temperature -20°C to +65°C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss ECtemp Touch and is the answer not in the manual?

Danfoss ECtemp Touch Specifications

General IconGeneral
Temperature sensorYes
Control typeTouch
Product colorWhite
Memory function-
International Protection (IP) codeIP21
Voltage220 - 240 V
Power sourceAC
Temperature control range5 - 45 °C