Danfoss ECtemp Touch
5Installation Guide
IP class 21
Protection class Class II -
Dimensions 85 x 85 x 20-24 mm
(in-wall depth: 22 mm)
Weight 103 g
Electrical safety and Electro-Magnetic Compatibility for
this product is covered by the compliance with the EN/IEC
Standard “Automatic electrical controls for household and
similar use”:
• EN/IEC 60730-1 (general)
• EN/IEC 60730-2-9 (thermostat)
1�2 Safety Instructions
Make sure the mains supply to the thermostat is turned o
before installation.
Important: When the thermostat is used to control a oor
heating element in connection with a wooden oor or
similar material, always use a oor sensor and never set the
maximum oor temperature to more than 35°C.
Please also note the following:
• The installation of the thermostat must be done by an
authorized and qualied installer according to local
regulations.