EasyManuals Logo
Home>Danfoss>Thermostat>EFIT 550

Danfoss EFIT 550 User Guide

Danfoss EFIT 550
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
26
5.0 Optional settings
5.1 Network setup
Each network must contain one (and only one) master unit
(MAS).
All other units must be either slave units (SLA) or independ-•
ent units (ALO).
Independent units in the network will not respond to •
or send information to a master unit. However, they still
count towards the network maximum of 32 units.
The following settings on all slave units are controlled from •
the master unit. All other settings must be configured on
each thermostat.
Time•
Weekday•
Economy set-back•
Network cables are unshielded, untwisted, and unpolarised •
two-wire cables for easy installation.
Installation manual

Other manuals for Danfoss EFIT 550

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss EFIT 550 and is the answer not in the manual?

Danfoss EFIT 550 Specifications

General IconGeneral
BrandDanfoss
ModelEFIT 550
CategoryThermostat
LanguageEnglish

Related product manuals