2 Manual RS8DZ602 © Danfoss 08-2010 EKC 202
Introduction
Application
The controller is used for temperature control refrigeration
appliances and cold room in supermarkets
• Control of defrost, fans, alarm and light
• For front panel mounting
Principle
The controller contains a temperature control where the signal
can be received from one temperature sensor.
The sensor is placed in the cold air ow after the evaporator or in
the warm air ow just before the evaporator.
The controller controls the defrost with either natural defrost or
electric defrost. Renewed cutin after defrost can be accomplished
based on time or temperature.
A measurement of the defrost temperature can be obtained
directly through the use of a defrost sensor.
Two to four relays will cut the required functions in and out – the
application determines which:
• Refrigeration (compressor or solenoid valve)
• Defrost
• Fan
• Alarm
• Light
The dierent applications are described on next page.
Advantages
Integrated refrigeration-technical functions
Defrost on demand in 1:1 systems
• Buttons and seal imbedded in the front
• IP65 density from the front panel
• Digital input for either:
- Door contact function with alarm
- Defrost start
- Start/stop of regulation
- Night operation
- Change-over between two temperature reference
- Case cleaning function
• Instant programming via programming key
• HACCP
Factory calibration that will guarantee a better measuring accu-
racy than stated in the standard EN 441-13 without subsequent
calibration (Pt 1000 ohm sensor)
Extra module
The controller can afterwards be tted with an insertion module
if the application requires it.
The controller has been prepared with plug, so the module
simply has to be pushed in
- Battery and buzzer module
The module guarantees voltage to the controller if the supply
voltage should drop out for more than four hours. The clock
function can thus be protected during a power failure.
- Data communication
If you require operation from a PC, a data communication mod-
ule has to be placed in the controller.
- Coordinated defrost via data communication
Contents
Introduction ....................................................................................................... 2
Operation ............................................................................................................ 5
Menu survey ....................................................................................................... 6
Functions ............................................................................................................. 8
Connections .....................................................................................................14
Data .....................................................................................................................15
Ordering ............................................................................................................16