User manual ERC 113 refrigeration controller
"FdC"
Min. -10.0 K
Max. 10.0 K
Default 0.0 K
Fan Δt cut in
Delta T for fan to cut in which the temperature offset comparing with
thermostat cut in temperature.
"Fdt"
Min. 0 s
Max. 999 s
Default 0 s
Fan stop time on door open
The delay with wich the fan will be stopped after the door has been opened.
"0": fan stop immediately when door open.
"1-998": delay for fan stop after door open.
"999": fan keep running all the time during door open.
Lig Light settings
"CLC"
Min. on
Max. dor
Default on
Cabinet Light Source Control
This parameter can be set to one of these alternatives to control the light
in the cabinet:
"on": always ON.
"oFF": always OFF.
"dor": door sensor only.
"Lod"
Min. 0 s
Max. 300 s
Default 0 s
Light OFF delay
Number of seconds the light will stay ON after the door has been closed.
Pud Pull Down settings
Pull down (sometimes known as Super Cool) is a procedure for improving
cooling performance, accelerating the time used to reach the desired
temperature. Pull down settings overrule all other settings.
"Pit"
Min. -40.0°C
Max. 50.0°C
Default 50.0°C
Pull Down Initiate Temperature
This parameter indicates the temperature which causes a pull
down to start. If the temperature measured inside the cabinet
exceeds this value for longer than one hour, then pull down will
start. The compressor will have already cut-in, so the only effect
is to stop defrost cycles until the desired temperature is reached.
The period of one hour is fixed and cannot be altered.
"PCy "
Min. 0 min
Max. 360 min
Default 30 min
Pull Down Cycling
This is the duration in minutes of the compressor cycling at the reduced
set point temperature. Once the desired pull down limit temperature
"PLt" has been reached during pull down, the compressor will continue to
cycle ON/OFF for the duration of "PCy". At the end of the period defined by
"PCy", the set point temperature will return to normal and pull down will
cease.
"Pdi"
Min. 0 hour
Max. 48 hour
Default 15 hour
Pull Down Defrost Interval
Even though most applications do not need Defrost during pull down, an
extended defrost during pull down can be applied. This is the time
between defrost cycles during pull down. It is measured in hours and can
be up to 48 hours.
During pull down, this setting overrides the defrost
interval and defrost time settings (see the defrost section).
"Pdd"
Min. 0 hour
Max. 48 hour
Default 24 hour
Pull Down Duration
You can choose to limit the maximum pull down time. Once this time
value (max. 48 hours) is reached, pull down will stop regardless of
whether the desired pull-down temperature has been reached.
"PLt"
Min. -55.0°C
Max. 55.0°C
Default 0.0°C
Pull Down Limit Temperature
This parameter sets the minimum allowed temperature during pull-down.
In order to protect valuable contents you must always specify the absolute
minimum temperature allowed in your application.
For glass door merchandisers 0°C/32°F protects bottles from freezing;
for commercial fridges you may opt for a slightly higher temperature
(e.g. 2°C)
8
DKRCC.ES.RL0.F5.02 Produced by Danfoss A/S (ADAP-KOOL®) | 2016-07