Compressor
Table 34: Compressor
Function
Code
Min.
Max.
Unit
AP0
AP1
AP2
AP3
AP4
AP5
AP6
AP7
Compressor
c--
Compressor minimum ON time
C01
0
30
min
0
0
0
0
0
0
0
0
Compressor minimum OFF time
C02
0
30
min
2
2
2
2
2
2
2
2
Compressor /Heater OFF delay at open door
C04
0
900
Secs
900
900
900
900
900
900
60
(1)
900
Zero crossing selection (YES / NO)
C70
no
YES
YES
YES
YES
YES
YES
YES
YES
(1)
YES
(1)
This option is a default setting in the controller and cannot be changed.
(1)
This option is a default setting in the controller and cannot be changed.
Others
Table 35: Others
Function
Code
Min.
Max.
Unit
AP0
AP1
AP2
AP3
AP4
AP5
AP6
AP7
Others
o--
Delay of outputs at startup
o01
0
600
sec
10
10
10
10
10
10
10
(1)
10
DI1 conguration
nC= Not congured; Sdc = Status display output,
doo = Door alarm with resumption, doA = Door
alarm without resumption, SCH = Main switch, nig
= Day/ Night mode, rFd = Reference displasement ,
EAL = External alarm, dEF = Defrost, Pud = Pull
down; Sc = Condensor Sensor
o02
nC
Sc
nC
nC
nC
nC
nC
nC
nC
nC
Serial address
o03
0
247
No
0
0
0
0
0
0
-
0.0
Password
o05
0
999
No
0
0
0
0
0
0
0
0
Sensor type selection (n5=NTC 5K, n10=NTC10K,
ptc=PTC, pt1=PT1000)
o06
(2)
n10
ptc
n10
n10
n10
n10
n10
n10
n10
n10
Cooling/Heating (rE=Cooling, Ht= Heating)
o07
(2)
rE
Ht
rE
rE
(1)
rE
(1)
rE
(1)
rE
(1)
rE
(1)
rE
Ht
(1)
Display Resolution
o15
0.1
1.0
0.1
0.1
0.1
0.1
0.1
0.1
0.1
(1)
0.1
DO4 cong (Lig=Light, ALA=Alarm)
o36
(2)
Lig
ALA
Lig
Lig
Lig
Lig
Lig
Lig
Lig
Lig
DI2 conguration
nC= Not congured; Sdc = Status display output,
doo = Door alarm with resumption, doA = Door
alarm without resumption, SCH = Main switch, nig
= Day/ Night mode, rFd = Reference displasement ,
EAL = External alarm, dEF = Defrost, Pud = Pull
down
o37
nC
Pud
nC
nC
nC
nC
nC
nC
nC
nC
Light Control
on= Always on, dAn = Day/Night, doo=Based on
door action
o38
on
doo
on
on
on
on
on
on
on
on
Predened applications
o61
(2)
AP0
AP7
AP0
AP1
AP2
AP3
AP4
AP4
AP6
AP7
Save settings as factory
o67
no
YES
no
no
no
no
no
no
-
no
DO2 cong (dEF=Defrost; ALA=alarm; Lig=Light)
o71
(2)
dEF
Lig
dEF
ALA
(1)
dEF
(1)
dEF
(1)
dEF
(1)
dEF
(1)
dEF
ALA
(1)
Display during defrost
o91
Air
-d-
-d-
-d-
-d-
-d-
-d-
-d-
-d-
(1)
-
(1)
This option is a default setting in the controller and cannot be changed.
(2)
This parameter can only be set when regulation is stopped, i.e. “r12” is set to 0
(1)
This option is a default setting in the controller and cannot be changed.
(2)
This parameter can only be set when regulation is stopped, i.e. “r12” is set to 0
Polarity
Table 36: Polarity
Function
Code
Min.
Max.
Unit
AP0
AP1
AP2
AP3
AP4
AP5
AP6
AP7
Polarity
P--
DI1 input polarity (nc/no)
no = normally open
nc = normally closed
P73
no
nc
no
no
no
no
no
no
no
no
DI2 input polarity (nc/no)
no = normally open
nc = normally closed
P74
no
nc
no
no
no
no
no
no
no
no
Invert alarm relay (0= normal, 1= invert relay ac-
tion)
P75
0
1
0
0
0
0
0
0
-
0.0
Key board lock (no / yes)(0=no, 1=yes)
P76
no
YES
no
no
no
no
no
no
-
no
© Danfoss | Climate Solutions | 2023.01 BC194286421698en-000901 | 29
Electronic refrigeration control, type ERC 21X

Other manuals for Danfoss ERC 211

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss ERC 211 and is the answer not in the manual?

Danfoss ERC 211 Specifications

General IconGeneral
BrandDanfoss
ModelERC 211
CategoryController
LanguageEnglish

Related product manuals