EasyManuals Logo
Home>Danfoss>Controller>Icon Series

Danfoss Icon Series User Manual

Danfoss Icon Series
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
© Danfoss | FEC | 2020.03
AN29434614196101-000401 | 088N2112 00 | 9
Installation Guide Danfoss Icon™ Master Controller 24V
EN
Technical data
Common characteristics, all Danfoss Icon™-products
Temperature for the ball pressure test 75 °C
Control polution degree Degree 2, normal household environment
Software class Class A
Rated impulse voltage 4 kV
Operating time Permanently connected
Temperature range, storage and transportation -20 °C to +65 °C
Dispossal instructions The product must be disposed as electronic waste.
Full data sheet available at www.danfoss.com
Radio Module & Repeater
Purpose of control Transmitting and receiving device
Ambient temperature range, continious use 0 °C to 40 °C
Frequency 868,4–869,85 MHz
Transmission power <2,5 mW
Encapsulation (IP Class) IP 20
Conformity declared acc. to following directives RED, RoHS, WEEE
Protection class Radio: Class III Construction, Repeater: Class II Construction
Supply voltage Radio: 5 V DC, Repeater: 230 V AC 50/60 Hz
App Module
Purpose of control Wi-Fi transmitting and receiving device, incl. Bluetooth
Ambient temperature range, continious use 0 °C to 40 °C
Frequency 2,4 GHz
Encapsulation (IP Class) IP 20
Conformity declared acc. to following directives RED, RoHS, WEEE
Protection class Radio: Class III
Supply voltage 5 V DC
Master Controller 24V and Expansion Module (optional)
Supply voltage 220-240 V AC
Supply frequency 50/60 Hz
Output voltage, actuators 24 V DC
Max. power consumption per actuator output 2 W
Number of actuator outputs (1 actuator per output terminal) 10 or 15 depending on type
Output voltage, thermostats 24 V DC
Stand-by consumption per thermostat 0,2 W
Max. number of thermostats 10 or 15 depending on type
Max. length of wire from master controller to a 24 V ther-
mostat (depends on cable type used)
If 2 × 2 × 0,6 mm² STP/UTP: 100 m
If 2 × 0,5 mm²: 150 m
If > 2 × 0,75 mm²: 200 m
Stand-by consumption, Master Controller < 2 W
Max. power consumption, excluding use of PWR 1 and PWR
2 outputs
< 50 W
Internal protection (fuse, non-replacable) 2,5 A
Output “Relay” Micro-disconnection (Type 1.B action), Max. 2 A load
Actuator outputs, type Electronic disconnection (Type 1.Y action)
Output “PWR 1”, type and rated max. output Micro-interruption (Type 1.C action)
Output “PWR 2, type and rated max. output Type: Permanent output, Always live 230 V, Max. 50 W
Output “PWR 3” (optional, on Expansion module – used for
dew point sensor)
24 V DC, max. 1 W
Input “1” (optional, on Expansion module – use varies acc. to
application chosen)
Ext. switch input (internal 24 V pull-up)
Input “2” (optional, on Expansion module – use varies acc. to
application chosen)
Ext. switch input (internal 24 V pull-up)
Input “3”, sensor input (optional, on Expansion module) External sensor, PT 1000 (Danfoss ESM 11)
Dimensions W: 370 mm, H: 100 mm, D: 53 mm
Conformity declared acc. to following directives LVD, EMC, RoHS and WEEE
Purpose of control Individual electronic room temperature control
Method of providing earthing Factory fitted power cord, incl. PE-conductor
Encapsulation (IP Class) IP 20
Protection class Class I
Ambient temperature range, continious use 0 °C to 50 °C
Wireless Thermostat
Purpose of control Room thermostat for room temperature control
Ambient temperature range, continious use 0 °C to 40 °C
Frequency 869 MHz
Transmission power <2,5 mW
Encapsulation (IP Class) IP 21
Supply voltage 2 × 1,5 V AA-Alkaline batteries
Conformity declared acc. to following directives RED, RoHS, WEEE
Protection class Class III
24V Wired Thermostat
Purpose of control Room thermostat for room temperature control
Ambient temperature range, continious use 0 °C to 40 °C
Encapsulation (IP Class) IP 21
Supply voltage 24 V DC
Conformity declared acc. to following directives EMC, RoHS, WEEE
Protection class Class III
External sensor NTC type, 47 kΩ @ 25 °C (Optional, 088U1110)

Table of Contents