EasyManuals Logo
Home>Danfoss>DC Drives>VLT 2800 Series

Danfoss VLT 2800 Series General Information

Danfoss VLT 2800 Series
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #106 background imageLoading...
Page #106 background image
Control card, analog inputs:
Number of analog voltage inputs 1 pcs.
Terminal number 53
Voltage level 0 - 10 V DC (scalable)
Input resistance, R
i
approx. 10 k
Max. voltage 20 V
Number of analog current inputs 1 pcs.
Terminal number 60
Current level 0/4 - 20 mA (scalable)
Input resistance, R
i
approx. 300
Max. current 30 mA
Resolution for analog inputs 10 bit
Accuracy of analog inputs Max. error 1% of full scale
Scan interval 13.3 msec
The analog inputs are galvanically isolated from the supply voltage (PELV) and other high-voltage terminals. See
section entitled Galvanic Isolation.
Control card, pulse inputs:
Number of programmable pulse inputs 1
Terminal number 33
Max. frequency on terminal 33 67.6 kHz (Push-pull)
Max. frequency on terminal 33 5 kHz (open collector)
Min. frequency on terminal 33 4 Hz
Voltage level 0 - 24 VDC (PNP positive logic)
Voltage level, logic '0' < 5 VDC
Voltage level, logic '1' > 10 VDC
Maximum voltage on input 28 VDC
Input resistance, R
i
approx. 2 k
Scan interval 13.3 msec
Resolution 10 bit
Accuracy (100 Hz - 1 kHz) terminal 33 Max. error: 0.5% of full scale
Accuracy (1 kHz - 67.6 kHz) terminal 33 Max. error: 0.1% of full scale
The pulse input (terminal 33) is galvanically isolated from the supply voltage (PELV) and other high-voltage terminals.
See section entitled Galvanic Isolation.
Control card, digital/frequency outputs:
Number of programmable digital/pulse outputs 1
Terminal number 46
Voltage level at digital/frequency output 0-24 V DC (O.C PNP)
Max. output current at digital/frequency output 25 mA.
Max. load at digital/frequency output
1 k
Max. capacity at frequency output 10 nF
Minimum output frequency at frequency output 16 Hz
Maximum output frequency at frequency output 10 kHz
Accuracy on frequency output Max. error: 0.2% of full scale
Resolution on frequency output 10 bit
The digital output is galvanically isolated from the supply voltage (PELV) and other high-voltage terminals. See section
entitled Galvanic Isolation.
VLT
®
2800 Series
106 MG.27.A2.22 - VLT
®
is a registered Danfoss trademark

Table of Contents

Other manuals for Danfoss VLT 2800 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT 2800 Series and is the answer not in the manual?

Danfoss VLT 2800 Series Specifications

General IconGeneral
BrandDanfoss
ModelVLT 2800 Series
CategoryDC Drives
LanguageEnglish

Related product manuals