FCM 300 / FCD 300 / VLT
®
2800 / DP V1 PROFIBUS
Parameter
list
PNU
#
Parameter
description
Factory setting 4-setup Conv.
index
Data
type
600 Operating hours No 73 7
601 Hours run No 73 7
602 kWh counte r No 2 7
603 Number of cut ins No 0 6
604 Number of overtemperatu res No 0 6
605 Number o f overvoltages No 0 6
615 Fault log: Error co de No 0 5
616 Fault log: Tim e No 0 7
617 Fault log: Value No 0 3
618 Reset of kWh counter No reset No 0 7
619 Reset of running hours counter No reset No 0 5
620 Operation mode Normal operation No 0 5
621 Nameplate: Unit type No 0 9
624 Nameplate: Software version No 0 9
625 Nameplate: LCP identification no. No 0 9
626 Nameplate: Database identification no. No -2 9
627 Nameplate: Power parts version No 0 9
628 Nameplate: Application option type No 0 9
630 Nameplate: Communication option type No 0 9
632 Nameplate: BMC so ftware identification No 0 9
634 Nameplate: Unit iden tification for communication No 0 9
635 Nameplate: Software parts no. No 0 9
640 Software version No -2 6
641 BMC software iden tification No -2 6
642 Power ca rd ident ification No -2 6
4-Setup:
’Yes ’ means that the parameter can be programmed
individually in each of the four S etups, i.e. one s ingle
parameter can have four different data values. No’
means that the data value will be the same in all Setups.
C
onversion index :
This number refers to a conversion figure to be used
when writing or reading via serial communication
with a frequency converter.
See Data character in Serial communic at ion
in the Design Guide.
D
ata type:
Data type shows the type and length of the telegram.
Data type Description
3 Integer 16
4 Integer 32
5Unsigned8
6Unsigned16
7Unsigned32
9Textstring
MG.90.A5.02 - VLT i s a registered Danfoss trademark
49