148 MG.30.A7.02 - VLT
®
is a registered Danfoss trademark
Mounting of
bonding plate for
UL approval
Insert the bonding plate into the cover as
shown.
Attach the bonding plate's ground wire with
the ground screw marked GND. The GND
screw is located to the right of the mains
terminal block.
Mount the bottom cover to the control.
Mounting of
fan option
Unplug the ribbon connector, the small
cable and the card ground wire.
Remove the control card and the shield
together.
Place the fan option on the extrusion, mak-
ing sure that the fan-option mounting holes
are aligned with the enclosure.
The next card has a two-pin molex connec-
tor placed as shown. Plug the fan
cable into the molex connector.
Replace the control card carefully, and
plug in the ribbon connector, the small
cable and the card’s ground wire.
Accessories