Synchronizing controller
50 MG.10.N4.02 - VLT is a registered Danfoss trademark
Function diagrams for position synchronization
SyncStart to a stationary master
If the slave is synchronized to a stationary master drive, the slave will remain stationary.
However, if a fixed offset is defined for the activated gear ratio, the slave travels to the extent of
this offset during synchronization.
Figure 17: Synchronizing to a stationary master
SyncStart to a running master
If synchronization is effected to a running master, the slave drive first makes up the deviation of
distance then it proceeds synchronously with the master. Any Offset setting is taken into
account.
Figure 18: Synchronizing to a running master