Synchronizing controller
68 MG.10.N4.02 - VLT is a registered Danfoss trademark
Parameter 744 Step width: In marker synchronization mode, Offset Parameter 740 is changed
by this value when Terminal 32 or Terminal 33 is activated.
Parameter 745 Slave speed factor: Record the factor by which the slave speed must be
multiplied, so that the desired value is displayed. To calculate the value use
the following formula:
Factor =
valueDisplay
resolutionerSlaveencodN
Set
_*60
_*400*
Example:
resolution 1024 increments, desired display 100 at 1500
1
/
min
Factor =
1500 400 1024
60 100
1
min
.
.
**
*
Inkr
Umdr
= 102400
Parameter 746 Master speed factor: Record the factor by which the master speed must be
multiplied, so that the desired value is displayed. To calculate the value use
the following formula:
Factor =
valueDisplay
resolutionderMasterencoN
Set
_*60
_*400*
Parameter 747 Synchronizing error display factor: Record the factor by which the error must
be multiplied, so that the desired value is displayed. To calculate the value,
use the following formula:
Factor =
valueDisplay
resolutionerSlaveencodN
Set
_*60
_*400*
Store your data settings by means of Store Input (I4) or by changing Parameter 710 to “1”.

Table of Contents

Other manuals for Danfoss VLT 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT 5000 and is the answer not in the manual?

Danfoss VLT 5000 Specifications

General IconGeneral
BrandDanfoss
ModelVLT 5000
CategoryController
LanguageEnglish

Related product manuals