The following messages are shown in online mode in the VLT® Motion Control Tool MCT 10:
Status of the safety option.
Internal and external errors and the corresponding troubleshooting tips.
To configure the LCP to show the safety option-specific information, use the parameters in parameter group 0-2* LCP Display.
Parameter 0-20 Display Line 1.1 Small to parameter 0-22 Display Line 1.3 Small have the following options:
Parameter 42-82 Safe Control Word
Parameter 42-83 Safe Status Word
Parameter 42-85 Active Safe Func
Parameter 0-23 Display Line 2 Large and parameter 0-24 Display Line 3 Large have the following options:
Parameter 42-82 Safe Control Word
Parameter 42-83 Safe Status Word
Parameter 42-86 Safe Option Info
9.4.1 LCP Status Messages
This section describes the LCP status messages related to the VLT® Safety Option MCB 152. The set of messages differs depending on
whether or not a safe fieldbus is enabled. Messages, which are shown regardless of the safe fieldbus state, are shown in table 23.
Messages, which are only shown when the safe fieldbus is disabled, are shown in table 24.
Table 23: LCP Messages
LCP Message Description
Sta
tus
0.0 Hz
50.0 %
!1(1)
0 R
PM 0.00 A 0.00KW
!
Safe S
t
op
[
W68]
Auto Remote Coast
e30be090.11
The safety function was activated via a digital input or via PROFIsafe.
Status
Safe Func. Pending
SO RESET required!
!1(1)
0 RPM 0.00 A 0.00KW
!Safe S
t
op
[
W68]
Auto Remote SO Req. RESET
e30be091.11
The source that triggered the safety condition has ceased, but the safety option is waiting for the
reset signal to continue normal operation. The LCP shows this message only if the manual restart
behavior is selected for the digital input. The LCP does not show this message when the PROFI-
safe control word activates the safety function, since the PROFIsafe configuration uses automatic
restart behavior.
Status
SO General Reset
SO RESET required!
!1(1)
0 RPM 0.00 A 0.00KW
!Safe S
t
op
[
W68]
Auto Remote SO Req. RESET
e30be092.11
The LCP shows this message after resetting the safety option with VLT® Motion Control Tool MCT
10. After the reset, the safety option is set to blank initial state. For more information, see 6.1.3
Password Protection.
Maintenance, Diagnostics, and
Troubleshooting
Installation Guide | VLT®Safety Option MCB 152
AN327351953089en-000101 / 130R0578| 69
Danfoss A/S © 2020.02

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 300 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 300 Series and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 300 Series Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 300 Series
CategoryDC Drives
LanguageEnglish

Related product manuals