6-72 Terminal 45 Digital Output
Option: Function:
Select the function of
terminal 45 as a digital
current output. See also
6-70 Terminal 45 Mode.
See
parameter 5-40 Function
Relay for descriptions of
the option.
[0] * No operation
[1] Control Ready
[2] Drive ready
[3] Drive rdy/rem ctrl
[4] Stand-by / no warning
[5] Running
[6] Running / no warning
[7] Run in range/no warn
[8] Run on ref/no warn
[9] Alarm
[10] Alarm or warning
[11] At torque limit
[12] Out of current range
[13] Below current, low
[14] Above current, high
[15] Out of frequency range
[16] Below frequency, low
[17] Above frequency, high
[18] Out of feedb. range
[19] Below feedback, low
[20] Above feedback, high
[21] Thermal warning
[22] Ready, no thermal warning
[23] Remote,ready,no TW
[24] Ready, no over-/ under voltage
[25] Reverse
[26] Bus OK
[27] Torque limit & stop
[28] Brake, no brake warning
[29] Brake ready, no fault
[30] Brake fault (IGBT)
[31] Relay 123
[32] Mech brake ctrl
[36] Control word bit 11
[37] Control word bit 12
[40] Out of ref range
[41] Below reference, low
[42] Above ref, high
[45] Bus ctrl.
[46] Bus control, timeout: On
[47] Bus control, timeout: Off
[56] Heat sink cleaning warning,
high
[60] Comparator 0
6-72 Terminal 45 Digital Output
Option: Function:
[61] Comparator 1
[62] Comparator 2
[63] Comparator 3
[64] Comparator 4
[65] Comparator 5
[70] Logic rule 0
[71] Logic rule 1
[72] Logic rule 2
[73] Logic rule 3
[74] Logic rule 4
[75] Logic rule 5
[80] SL digital output A
[81] SL digital output B
[82] SL digital output C
[83] SL digital output D
[160] No alarm
[161] Running reverse
[165] Local ref active
[166] Remote ref active
[167] Start command activ
[168] Drive in hand mode
[169] Drive in auto mode
[170] Homing Completed
[171] Target Position Reached
[172] Position Control Fault
[173] Position Mech Brake
[174] TLD indicator
[175] Running on tension
[176] Ready to run
[177] End of roll
[193] Sleep Mode
[194] Broken Belt Function
[198] Drive Bypass
6-92 Terminal 42 Digital Output
Option: Function:
[0] * No operation
[1] Control Ready
[2] Drive ready
[3] Drive rdy/rem ctrl
[4] Stand-by / no warning
[5] Running
[6] Running / no warning
[7] Run in range/no warn
[8] Run on ref/no warn
[9] Alarm
[10] Alarm or warning
[11] At torque limit
[12] Out of current range
[13] Below current, low
[14] Above current, high
[15] Out of frequency range
Positioning Control Application Guide
MG06E102 Danfoss A/S © 11/2014 All rights reserved. 23
4 4

Other manuals for Danfoss VLT AutomationDrive FC 360

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 360 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 360 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 360
CategoryDC Drives
LanguageEnglish

Related product manuals