33-43 Negative Software Limit Active
When this parameter is set to active, the frequency converter
continuously checks whether the target position is below the
negative software limit. If it occurs, an error is issued and the
frequency converter control is switched off.
Option: Function:
[0] * Inactive
[1] Active
33-44 Positive Software Limit Active
When this parameter is set to active, the frequency converter
continuously checks whether the target position is above the
positive software limit. If it occurs, an error is issued and the
frequency converter control is switched off.
Option: Function:
[0] * Inactive
[1] Active
33-47 Target Position Window
Defines the size of the target window with user unit. A position
is only viewed as reached when the actual position is within this
window.
Range: Function:
0* [0 - 10000 ]
4.7.5 34-** Motion Control Data Readouts
34-01 PCD 1 Write For Application
Range: Function:
0* [0 - 65535 ]
34-02 PCD 2 Write For Application
Range: Function:
0* [0 - 65535 ]
34-03 PCD 3 Write For Application
Range: Function:
0* [0 - 65535 ]
34-04 PCD 4 Write For Application
Range: Function:
0* [0 - 65535 ]
34-05 PCD 5 Write For Application
Range: Function:
0* [0 - 65535 ]
34-06 PCD 6 Write For Application
Range: Function:
0* [0 - 65535 ]
34-07 PCD 7 Write For Application
Range: Function:
0* [0 - 65535 ]
34-08 PCD 8 Write For Application
Range: Function:
0* [0 - 65535 ]
34-09 PCD 9 Write For Application
Range: Function:
0* [0 - 65535 ]
34-10 PCD 10 Write For Application
Range: Function:
0* [0 - 65535 ]
34-21 PCD 1 Read For Application
Range: Function:
0* [0 - 65535 ]
34-22 PCD 2 Read For Application
Range: Function:
0* [0 - 65535 ]
34-23 PCD 3 Read For Application
Range: Function:
0* [0 - 65535 ]
34-24 PCD 4 Read For Application
Range: Function:
0* [0 - 65535 ]
34-25 PCD 5 Read For Application
Range: Function:
0* [0 - 65535 ]
34-26 PCD 6 Read For Application
Range: Function:
0* [0 - 65535 ]
34-27 PCD 7 Read For Application
Range: Function:
0* [0 - 65535 ]
34-28 PCD 8 Read For Application
Range: Function:
0* [0 - 65535 ]
34-29 PCD 9 Read For Application
Range: Function:
0* [0 - 65535 ]
34-30 PCD 10 Read For Application
Range: Function:
0* [0 - 65535 ]
34-50 Actual Position
The actual position in user unit.
Range: Function:
0* [-1073741824 - 1073741824 ]
Positioning Control
VLT
®
AutomationDrive FC 360
26 Danfoss A/S © 11/2014 All rights reserved. MG06E102
44

Other manuals for Danfoss VLT AutomationDrive FC 360

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 360 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 360 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 360
CategoryDC Drives
LanguageEnglish

Related product manuals