Option
Name
Description
[5]
57600 Baud
[6]
76800 Baud
[7]
115200 Baud
Parameter 8-33 Parity/Stop Bits
Table 512: Parameter 8-33 Parity/Stop Bits
8-33 Parity/Stop Bits
Default value: [0] Even parity, 1 stop bit
Parameter type: Option
Setup: 1 setup
Conversion index: –
Data type: Uint8
Change during operation: True
Option
Name
Description
[0]*
Even parity, 1 stop bit
[1]
Odd parity, 1 stop bit
[2]
No parity, 1 stop bit
[3]
No parity, 2 stop bits
Parameter 8-34 Estimated Cycle Time
Table 513: Parameter 8-34 Estimated Cycle Time
8-34 Estimated Cycle Time
Default value: 0 ms
Parameter type: Range, 0 - 1000000 ms
Setup: 2 setups
Conversion index: -3
Data type: Uint32
Change during operation: True
In noisy environments, the interface may be blocked due to overload or bad frames. This parameter specifies the time between 2
consecutive frames on the network. If the interface does not detect valid frames in that time, it flushes the receive buffer.
Parameter 8-35 Minimum Response Delay
Table 514: Parameter 8-35 Minimum Response Delay
8-35 Minimum Response Delay
Default value: 10 ms
Parameter type: Range, 1 - 10000 ms
Setup: 1 setup
Conversion index: -3
Data type: Uint16
Change during operation: True
Specify the minimum delay time between receiving a request and transmitting a response. This is used for overcoming modem
turnaround delays.
Parameter 8-36 Max Response Delay
Table 515: Parameter 8-36 Max Response Delay
8-36 Max Response Delay
Default value: Size related
Parameter type: Range, 11 - 10001 ms
Setup: 1 setup
Conversion index: -3
Data type: Uint16
Change during operation: True
Specify the maximum allowed delay time between transmitting a request and receiving a response. If a response from the drive
exceeds the time setting, then it is discarded.
AU275636650261en-000101 / 130R0334288 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide

Table of Contents

Other manuals for Danfoss VLT CANopen MCA 105

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT CANopen MCA 105 and is the answer not in the manual?

Danfoss VLT CANopen MCA 105 Specifications

General IconGeneral
BrandDanfoss
ModelVLT CANopen MCA 105
CategoryDC Drives
LanguageEnglish

Related product manuals