N O T I C E
If [20] Alarm number or [21] Warning number is selected in parameter 3-10 Comparator Operand, [2] >
cannot be selected in this parameter.
Inverse logic of option [0] <.
Parameter 13-12 Comparator Value
Table 676: Parameter 13-12 Comparator Value
Default value: Size related
Parameter type: Range, -100000.000 - 100000, Array [10]
Change during operation: True
Enter the trigger level for the variable that is monitored by this comparator. This is an array parameter containing comparator values
0–9.
5.13.2.1 RS FlipFlops
The reset/set flipflops hold the signal until set/reset.
Parameter 13-15
RS-FF Operand S
Parameter 13-16
RS-FF Operand R
e30bb959.11
Illustration 80: Reset/Set Flipflops
Two parameters are used and the output can be used in the logic rules and as events.
R
S
Flip flop output
e30bb960.11
Illustration 81: Flipflop Outputs