Parameter 36-22 Terminal X49/3 High Voltage
Table 1318: Parameter 36-22 Terminal X49/3 High Voltage
36-22 Terminal X49/3 High Voltage
Default value: 10 V
Parameter type: Range, 0 - 10 V
Setup: All setups
Conversion index: 0
Data type: Int16
Change during operation: True
Parameter 36-23 Terminal X49/3 High Current
Table 1319: Parameter 36-23 Terminal X49/3 High Current
36-23 Terminal X49/3 High Current
Default value: 20 mA
Parameter type: Range, 0 - 20 mA
Setup: All setups
Conversion index: -3
Data type: Int16
Change during operation: True
Parameter 36-24 Terminal X49/3 Low Ref./Feedb. Value
Table 1320: Parameter 36-24 Terminal X49/3 Low Ref./Feedb. Value
36-24 Terminal X49/3 Low Ref./Feedb. Value
Default value: 0 ReferenceFeedbackUnit
Parameter type: Range, -999999.999 - 999999.999
ReferenceFeedbackUnit
Setup: All setups
Conversion index: 0
Data type: Int32
Change during operation: True
Parameter Parameter 36-25 Terminal X49/3 High Ref./Feedb. Value
Table 1321: Parameter 36-25 Terminal X49/3 High Ref./Feedb. Value
36-25 Terminal X49/3 High Ref./Feedb. Value
Default value: 100 ReferenceFeedbackU-
nit
Parameter type: Range, -999999.999 - 999999.999
ReferenceFeedbackUnit
Setup: All setups
Conversion index: 0
Data type: Int32
Change during operation: True
Parameter 36-26 Term. X49/3 Filter Time Constant
Table 1322: Parameter 36-26 Term. X49/3 Filter Time Constant
36-26 Term. X49/3 Filter Time Constant
Default value: 0.001 s
Parameter type: Range, 0.001 - 10 s
Setup: All setups
Conversion index: 0
Data type: Uint16
Change during operation: True
Enter the filter time constant. This is a first-order digital low-pass filter time constant for suppressing electrical noise in terminal
X49/3. A high time constant value improves dampening but also increases the time delay through the filter.
5.29.4 36-3* Analog Input X49/5
N O T I C E
This parameter group is only available in FC 302.
AU275636650261en-000101 / 130R0334 | 641Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide

Table of Contents

Other manuals for Danfoss VLT CANopen MCA 105

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT CANopen MCA 105 and is the answer not in the manual?

Danfoss VLT CANopen MCA 105 Specifications

General IconGeneral
BrandDanfoss
ModelVLT CANopen MCA 105
CategoryDC Drives
LanguageEnglish

Related product manuals