Q3-3 Closed Loop Settings
Q3-30 Single Zone Int. Set Point Q3-31 Single Zone Ext. Set Point Q3-32 Multi Zone / Adv
1-00 Configuration Mode 1-00 Configuration Mode 1-00 Configuration Mode
20-12 Reference / Feedback Unit 20-12 Reference / Feedback Unit 3-15 Reference 1 Source
20-13 Minimum Reference/Feedb. 20-13 Minimum Reference/Feedb. 3-16 Reference 2 Source
20-14 Maximum Reference/Feedb. 20-14 Maximum Reference/Feedb. 20-00 Feedback 1 Source
6-22 Terminal 54 Low Current 6-10 Terminal 53 Low voltage 20-01 Feedback 1 Conversion
6-24 Terminal 54 Low ref/feedb Value 6-11 Terminal 53 High voltage 20-02 Feedback 1 Source Unit
6-25 Terminal 54 High ref/feedb Value 6-12 Terminal 53 Low Current 20-03 Feedback 2 Source
6-26 Terminal 54 Filter Time Constant 6-13 Terminal 53 High Current 20-04 Feedback 2 Conversion
6-27 Terminal 54 Live Zero 6-14 Terminal 53 Low ref/feedb. Value 20-05 Feedback 2 Source Unit
6-00 Live zero Timeout Time 6-15 Terminal 53 High ref/feedb. Value 20-06 Feedback 3 Source
6-01 Live zero Timeout Function 6-22 Terminal 54 Low Current 20-07 Feedback 3 Conversion
20-21 Setpoint 1 6-24 Terminal 54 Low ref/feedb Value 20-08 Feedback 3 Source Unit
20-81 PID Normal / Inverse Control 6-25 Terminal 54 High ref/feedb Value 20-12 Reference / Feedback Unit
20-82 PID Start Speed [RPM] 6-26 Terminal 54 Filter Time Constant 20-13 Minimum Reference/Feedb.
20-83 PID Start Speed [Hz] 6-27 Terminal 54 Live Zero 20-14 Maximum Reference/Feedb.
20-93 PID Proportional Gain 6-00 Live zero Timeout Time 6-10 Terminal 53 Low Voltage
20-94 PID Integral Time 6-01 Live Zero Timeout Function 6-11 Terminal 53 High Voltage
20-81 PID Normal / Inverse Control 6-12 Terminal 53 Low Current
20-82 PID Start Speed [RPM] 6-13 Terminal 53 High Current
20-83 PID Start Speed [Hz] 6-14 Terminal 53 Low ref/feedb. Value
20-93 PID Proportional Gain 6-15 Terminal 53 High ref/feedb. Value
20-94 PID Integral Time 6-16 Terminal 53 Filter Time
6-17 Terminal 53 Live Zero
6-20 Terminal 54 Low Voltage
6-21 Terminal 54 High Voltage
6-22 Terminal 54 Low Current
6-23 Terminal 54 High Current
6-24 Terminal 54 Low ref/feedb.
6-25 Terminal 54 High ref/feedb. Value
6-26 Terminal 54 Filter Time
6-27 Terminal 54 Live Zero
6-00 Live zero Timeout Time
6-01 Live zero Timeout Function
4-56 Warning Feedback Low
4-57 Warning Feedback High
20-20 Feedback Function
20-21 Setpoint 1
20-22 Setpoint 2
20-81 PID Normal / Inverse Control
20-82 PID Start Speed [RPM]
20-83 PID Start Speed [Hz]
20-93 PID Proportional Gain
20-94 PID Integral Time
20-70 Closed Loop Type
20-71 PID Performance
20-72 PID Output Change
20-73 Minimum Feedback Level
20-74 Maximum Feedback Level
20-79 PID Autotuning
2. How to Programme VLT
®
HVAC Drive Programming Guide
18
MG.11.C5.02 - VLT
®