1.8 General Technical Data
Protection and features
•
Electronic thermal motor protection against overload.
•
Temperature monitoring of the heatsink ensures that the frequency converter trips in case of overtemperature.
•
The frequency converter is protected against short-circuits between motor terminals U, V, W.
•
If a motor phase is missing, the frequency converter trips and issues an alarm.
•
If a mains phase is missing, the frequency converter trips or issues a warning (depending on the load).
•
Monitoring of the intermediate circuit voltage ensures that the frequency converter trips if the intermediate circuit
voltage is too low or too high.
•
The frequency converter is protected against earth faults on motor terminals U, V, W.
Mains supply (L1/L, L2, L3/N):
Supply voltage 200-240V ±10%
Supply voltage 380-480V ±10%
Supply frequency 50/60Hz
Max. imbalance temporary between mains phases 3.0% of rated supply voltage
True Power Factor (λ) ≥ 0.4 nominal at rated load
Displacement Power Factor (cosφ) near unity (> 0.98)
Switching on input supply L1/L, L2, L3/N (power-ups) maximum 2 times/min.
Environment according to EN60664-1 overvoltage category III/pollution degree 2
The unit is suitable for use on a circuit capable of delivering not more than 100.000 RMS symmetrical Amperes, 240/480V
maximum.
Motor output (U, V, W):
Output voltage 0 - 100% of supply voltage
Output frequency 0-200Hz (VVC+), 0-400Hz (u/f)
Switching on output Unlimited
Ramp times 0.05 - 3600sec.
Cable lengths and cross sections:
Max. motor cable length, screened/armoured (EMC correct installation) 15m
Max. motor cable length, unscreened/unarmoured 50m
Max. cross section to motor, mains*
Connection to load sharing/brake (M1, M2, M3) 6.3mm insulated Faston Plugs
Max. cross section to load sharing/brake (M4, M5) 16mm
2
/6AWG
Maximum cross section to control terminals, rigid wire 1.5mm
2
/16 AWG (2 x 0.75mm
2
)
Maximum cross section to control terminals, flexible cable 1mm
2
/18 AWG
Maximum cross section to control terminals, cable with enclosed core 0.5mm
2
/20AWG
Minimum cross section to control terminals 0.25mm
2
* See tables for mains supply for more information!
Digital Inputs (Pulse/Enocder Inputs):
Programmable digital inputs (Pulse/encoder) 5 (1)
Terminal number 18, 19, 27, 29, 33,
Logic PNP or NPN
Voltage level 0 - 24V DC
Voltage level, logic'0' PNP < 5V DC
Voltage level, logic'1' PNP > 10V DC
Voltage level, logic '0' NPN > 19V DC
Voltage level, logic '1' NPN < 14V DC
Maximum voltage on input 28V DC
Input resistance, R
i
approx. 4k
Max. pulse frequency at terminal 33 5000Hz
Min. pulse frequency at terminal 33 20Hz