Installation, use and maintenance manual
25
2 TECHNICAL
SPECIFICATIONS
Detectable spectrum 850 .. 1700 nm
Temperature of the object to be
detected
≥ 450°C (842°F) HIGH sensitivity
≥ 650°C (1202°F) LOW sensitivity
Distance of detection (fig. 7) 500 .. 2,000 mm
Range of the observation field (fig. 8)
vertical: 12°
horizontal: 3°
Digital inputs 24 Vdc / 5 mA
Digital outputs
PNP, Imax = 200 mA, output connections protected
against short circuits.
Response time
ON
OFF
typ. 0.2 ms (min 0.1, max 0.3 ms)
typ. 0.3 ms (min 0.2, max 0.5 ms)
Power supply rated voltage 24 Vdc (20 .. 32Vdc) @ 50mA
Power supply of cooling device
water, filtered < 300 µm, 3-5 L/min @ 0.2 bar, 2 bar max
1/4” GAS threads
Working temperature -40 .. +70 °C (-40 .. 158 °F)
Storage temperature -40 .. +70 °C (-40 .. 158 °F)
Degree of protection IP66 (NEMA 4X)
Dimensions (not including connectors) 266 x 180 x 64 mm (10.5” x 7.1” x 2.5”)
Weight 1.7 kg (3.7 lb)
Danieli Automation Standard - Installation Use and Maintenance Manual - ID2202
Certified by OneDoc A.620.107 Rev.04-MU 26/145 #1061394