Chapter 3 - Printer Operation 29
Advanced Entry Calibration (continued)
Step Action Displayed Message Comment
L
Use the buttons to set the Gain
Number determined in the
previous step. Press ENTER to
enable the setting.
TRAN SENSOR GAIN
yyy (0 - 31)
18
This example uses Gain Number
18.
M
Complete a table (see example
below) using new measurements,
as follows:
(A) Raise the Printhead Assembly.
Place the label over the Media
Sensor then lower and latch the
Printhead Assembly. Record the
sensor reading as P.
(B) Raise the Printhead Assembly.
Place the liner, notch, or mark
over the Media Sensor then lower
and latch the Printhead Assembly.
Record the sensor reading as G (or
M).
(C) Raise the Printhead Assembly.
Remove all media from the Media
Sensor then lower and latch the
Printhead Assembly. Record the
sensor reading as E.
TRAN SENSOR GAIN
yyy (0 - 31)
18
Where “yyy” is a numerical value
representing the current sensor
reading.
The re-sampled values may
differ from those previously
noted. This is normal; do not
readjust the Media Sensor.
Selected Gain Table
Gain Number Paper Gap (or Mark) Empty
18 173 42 9