Extended System-Level Command Functions
102 Class Series 2 Programmer’s Manual
STX KD Database Configuration (Non-Display Models only)
This command, stored in Flash memory for future power-ups, controls the printer’s
environment and operates as a pseudo DIP switch. The <STX>Kc command is
recommended for use over <STX>KD.
Syntax:
<STX>KDwxyz<CR>
Where:
w, x, y, and z are binary values with respective bit settings as
defined in the following table. (Bit 0 is least significant.)
Sample:
<STX>KD@H@@<CR>
The sample above configures 9600 baud, 8-bit words, no parity,
with direct thermal printing, gap sensing, standard control
characters, and a cutter.
Ignore Host Distance (see below) disregards <STX>O and <STX>f commands (in case
host software sends values that may be inappropriate). Use the <STX>KD command or
the Setup Menu to enable this feature.
This command will result in a system reset for the EX2.
<STX>KD
Parameter
Bit
Number
Function Value(s)
0 – 2 BAUD Rate / Set Test Mode
0 = 9600, 1 = 600, 2 = 2400,
3 = 19200, 4 = 4800, 5 = 38400,
6 = 1200, 7 = 9600 Test Mode
3 Word Length and Parity
0 = 8 bits, no parity;
1 = 7 bits, even parity
4 & 5 Unused Set to 0
6 Always 1 Set to 1
w
7 Always 0 Set to 0
0 Print Method 0 = direct thermal, 1 = thermal transfer
1 Present Sensor 0 = not equipped, 1 = equipped
2 Control Character
[1]
0 = standard, 1 = Alternate characters
3 Cutter 0 = disabled, 1 = enabled
4 Ignore Host Distance
0 = disabled,
1 = enabled (see note above)
5 Alt-2 Control Codes
[1]
0 = disabled,
1 = Alternate-2 characters
6 Always 1 Set to 1
x
7 Always 0 Set to 0
0 & 1 Sensor Type 0 = gap, 1 = reflective, 2 = continuous
2 Linerless 0 = not equipped, 1 = equipped
3 – 5 Unused Set to 0
6 Always 1 Set to 1
y
7 Always 0 Set to 0
0 & 1 Reserved Set to 0
2 Reserved Set to 0
3 – 5 Unused Set to 0
6 Always 1 Set to 1
z
7 Always 0 Set to 0
[1]
Selects the values of the control characters; see Control Code Command Functions.
Table 5-15: Database Configuration Command

Table of Contents

Other manuals for Datamax MP Compact4 Mark II

Question and Answer IconNeed help?

Do you have a question about the Datamax MP Compact4 Mark II and is the answer not in the manual?

Datamax MP Compact4 Mark II Specifications

General IconGeneral
Print MethodDirect Thermal
Maximum Print Width4.1 inches (104 mm)
Media Typedie-cut, fan-fold, tag stock
Media Thickness0.0025" (0.0635 mm) to 0.01" (0.254 mm)
Media Roll Diameter5 inches (127 mm) max
Ribbon Length984 feet (300 meters)
Processor32-bit RISC
InterfacesUSB, Serial RS232
Optional InterfacesWireless (802.11 b/g/n), Bluetooth
Power Supply100-240 VAC, 50/60 Hz
Operating Temperature41 to 104°F (5 to 40°C)
Supported Barcode TypesUPC-A, UPC-E, EAN-13, EAN-8, Code 39, Code 128, Interleaved 2 of 5, Codabar, PDF417, Data Matrix, QR Code, MaxiCode, Aztec
Print Resolution203 dpi (8 dots/mm) or 300 dpi (12 dots/mm)
Ribbon Width1" (25.4 mm) to 4.3" (110 mm)