Page #120 background image
Extended System-Level Command Functions
108 Class Series 2 Programmer’s Manual
STX KI GPIO Input
This command configures the GPIO input channels of the Applicator Interface Card; see
Appendix J for details.
Syntax:
<STX>KIffnspwww<CR>
ff
- 2 character function name abbreviation (e.g., PS [Print
Start], I1 [User Input 1], etc).
n
- Pin number, where 1 – 8 is the valid range.
s
- Signal type, where: L = Level; P = Positive Pulse;
and N = Negative Pulse
p
- Polarity, where: 0 = Active Low; and 1 = Active High
Where:
www
- 3 character filter pulse width, in milliseconds.
STX Kn NIC Reset
This command resets the NIC to factory defaults.
Syntax:
<STX>Knx
Where:
x
- Specifies the action, where:
F = Returns the NIC to the factory default settings; or,
H = Reports settings to host (wireless, only).
Address
Default Values
Wired Ethernet*
Default Values
Wireless Ethernet
IP
192.168.010.026 192.168.010.001
Subnet Mask
255.255.255.000 255.255.255.000
Gateway
000.000.000.000 000.000.000.000
* Prior to introduction of the Wireless Ethernet, 192.0.0.192
was the IP default value and the Subnet Mask was 0.0.0.0.

Table of Contents

Other manuals for Datamax MP Compact4 Mark II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datamax MP Compact4 Mark II and is the answer not in the manual?

Datamax MP Compact4 Mark II Specifications

General IconGeneral
BrandDatamax
ModelMP Compact4 Mark II
CategoryPrinter
LanguageEnglish

Related product manuals