System-Level Command Functions
34 Class Series 2 Programmer’s Manual
STX x Delete File from Module
This command removes a specific file from the specified module. The file name is
removed from the module directory and thus the file cannot be accessed. The actual
storage space occupied by the file is not released. To reclaim deleted file storage space
use <STX>z to pack the module.
Syntax:
<STX>xmtnn…n<CR>
Where:
m
-
Module designator; see Appendix K.
t
-
The file type identification code:
G
L
F
S
C
X
N
M
u
=
=
=
=
=
=
=
=
=
Image file
Label format file
Downloaded bitmapped font file
Downloaded scalable font file
Configuration file
Language file
Plug-in file
Miscellaneous file type
Unknown type – must use extension if
applicable
nn…n -
The file to delete, where:
Font (bitmapped), three character font identifier;
Font (scalable), two character font identifier;
Graphic name, up to sixteen alphanumeric
characters; or,
Label format name, up to sixteen alphanumeric
characters.
Sample:
<STX>xDS50<CR>
The sample above deletes a downloaded scalable font with ID 50
from Module D.

Table of Contents

Other manuals for Datamax MP Compact4 Mark II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datamax MP Compact4 Mark II and is the answer not in the manual?

Datamax MP Compact4 Mark II Specifications

General IconGeneral
BrandDatamax
ModelMP Compact4 Mark II
CategoryPrinter
LanguageEnglish

Related product manuals