16 SCG1000 | Dell Networking S4810 and Force10 S4810 Configuration Guide for EqualLogic SANs
5.8 Configure login credentials
FTOS(conf)#username admin privilege 15 password 0 yourpassword
FTOS(conf)#enable password level 15 0 yourpassword
5.9 Configuring switch ports
FTOS(conf)#interface range tengigabitethernet 0/0 47
FTOS(conf-if-range-te-0/0-47)#mtu 12000
FTOS(conf-if-range-te-0/0-47)#switchport
FTOS(conf-if-range-te-0/0-47)#spanning-tree rstp edge-port
FTOS(conf-if-range-te-0/0-47)#flowcontrol rx on tx off
FTOS(conf-if-range-te-0/0-47)#no shutdown
FTOS(conf-if-range-te-0/0-47)#exit
FTOS(conf)#interface range tengigabitethernet 1/0 47
FTOS(conf-if-range-te-1/0-47)#mtu 12000
FTOS(conf-if-range-te-1/0-47)#switchport
FTOS(conf-if-range-te-1/0-47)#spanning-tree rstp edge-port
FTOS(conf-if-range-te-1/0-47)#flowcontrol rx on tx off
FTOS(conf-if-range-te-1/0-47)#no shut
FTOS(conf-if-range-te-1/0-47)#exit
FTOS(conf)#protocol spanning-tree rstp
FTOS(conf-rstp)#no disable
FTOS(conf-rstp)#exit
FTOS(conf)#exit
5.10 Save configuration and reload
FTOS#copy running-config startup-config
Reload the stack to allow settings to take effect:
FTOS#reload
Note: The preceding procedure places all switch ports in the default VLAN. If you prefer to place ports in
a non-default VLAN, refer to the documentation for your switch.

Table of Contents

Other manuals for Dell Networking S4810

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell Networking S4810 and is the answer not in the manual?

Dell Networking S4810 Specifications

General IconGeneral
BrandDell
ModelNetworking S4810
CategorySwitch
LanguageEnglish

Related product manuals