To view the Asset Tag utility help screen, type asset /? and press <Enter>.
Baseboard Management Controller Configuration
The Baseboard Management Controller (BMC) enables you to configure, monitor, and recover systems remotely. BMC provides the following features:
l Uses the system's serial port and integrated NIC
l Fault logging and SNMP alerting
l Access to system event log and sensor status
l Control of system functions including power on and off
l Support is independent of the system's power or operating state
l Text console redirection for system setup, text-based utilities, and operating system consoles
For additional information on using BMC, see the documentation for the BMC and systems management applications.
Entering the BMC Setup Module
1. Turn on or restart your system.
2. Press <Ctrl-E> when prompted after POST.
If your operating system begins to load before you press <Crtl-E>, allow the system to finish booting, and then restart your system and try again.
BMC Setup Module Options
Table3-7 lists the BMC Setup Module options and shows how to configure the emergency management port (EMP).
Table 3-7.BMCSetupModule
Back to Contents Page
NOTE: To use the BMC feature, you must connect the network connection to integrated NIC1. See Figure1-3.
Option
Description
Static IP Vs DHCP
Source
Displays whether the network controller will be assigned a static IP address or a DHCP address
BMC IP Address
Enter the IP address for a static IP address. The field is limited to a maximum value of 255.255.255.255. If IP address 169.254.0.6 is
used and DCHP is enabled, the BMC will not be able to contact the DHCP server.
Subnet Mask
Enter the subnet mask for the static IP address.
Gateway
Enter the IP gateway for the static IP address.
Alert IP Address
Displays the address of the alert destination.
LAN Channel
Enables or disables the out-of-band LAN channel access to the shared network controller.
UserID2 Account
Modifies the administrator account's username and password.
BMC GUID
Displays the system's global unique identifier.
MAC Address
Displays the network controller's MAC address.
Reset BMC settings
to default
Clears the BMC settings and resets the BMC setting to the defaults.
NOTE: If the integrated network controller is used in an Ether Channel team or link aggregation team, the BMC management traffic will not function
properly. For more information about network teaming, see the documentation for the network controller.

Other manuals for Dell PowerEdge 2850

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge 2850 and is the answer not in the manual?

Dell PowerEdge 2850 Specifications

General IconGeneral
ProcessorIntel Xeon
Processor SpeedUp to 3.6 GHz
ChipsetIntel E7520
MemoryUp to 16GB DDR2
NetworkDual embedded Broadcom Gigabit Ethernet
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server
RAIDPERC 4e/DC
Power SupplyRedundant
Form Factor2U Rack
StorageUp to 1.8TB (6 x 300GB SAS HDDs)