12
fused plug having a fuse of 13 amp capacity. Should this plug not t the socket outlets in your home, it should be cut o and replaced
with a suitable plug, following the procedure outlined below.
Note: Such a plug cannot be used for any other appliance and should therefore be properly disposed of and not left where children
might nd it and plug it into a supply socket - with the obvious consequent danger.
Please note: We recommend the use of good quality plugs and wall sockets that can be switched o when the machine is not in use.
IMPORTANT: The wires in the mains lead tted to this appliance are coloured in accordance with the following code:
GREEN AND YELLOW EARTH
As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the termi-
nals in your plug, proceed as follows:
- The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or
by the earth symbol or coloured green or green and yellow.
- The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black.
- The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red.
When wiring the plug, ensure that all strands of wire are securely retained in each terminal. Do not forget to tighten the mains lead
clamp on the plug. If your electricity supply point has only two pin socket outlets, or if you are in doubt, consult a qualied electrician.
Should the mains lead ever require replacement, it is essential that this operation be carried out by a qualied electrician and should
only be replaced with a exible cord of the same size. After replacement of a fuse in the plug, the fuse cover must be retted. If the
fuse cover is lost, the plug must not be used until a replacement cover is obtained. The colour of the correct replacement fuse cover
is that of the coloured insert in the base of the fuse recess or elsewhere on the plug. Always state this colour when ordering a repla-
the Norms EN 55014 regarding the suppression of radio interference.
Warning - this appliance must be earthed
Green and Yellow to Earth
13 amp Fuse
Brown to live
Cord Clamp
Blue to
neutral
en
electrical requirements
Problem Possible cause Solution
The coee crema is dark (it ows
slowly from the spout)
The ground coee is too tightly pressed Tamper the coee less (g. 10)
Too much ground coee Decrease the amount of ground coee
The espresso boiler outlet is blocked Clean as indicated in the “Cleaning the espresso
boiler outlet” chapter.
The lter is blocked Clean as indicated in the “cleaning the lter” par.
The coee is too nely ground Only use coee ground specically for espresso
coee machines
The ground coee is too ne or is damp Only use coee ground specically for espresso
coee machines and it must not be too damp
Incorrect type of ground coee Change the quality of the ground coee powder