Page #19 background imageLoading...
Page #19 background image
19
Fig. 44
Fig. 45
BRUSH INSPECTION
AND REPLACEMENT
CAUTION: BEFORE INSPECTING BRUSHES, DIS-
CONNECT THE MACHINE FROM THE POWER
SOURCE.
Brush life varies. It depends on the load on the motor.
Check the brushes after the first 50 hours of use for a
new machine or after a new set of brushes has been
installed.
After the first check, examine them after about 10 hours
of use until such time that replacement is necessary.
The brush holders (A) Fig. 44, are located on the motor
housing opposite each other. Fig. 45, illustrates one of
the brushes removed for inspection. When the carbon on
either brush is worn to 3/16" in length or if either spring or
shunt wire is burned or damaged in any way, replace both
brushes. If the brushes are found serviceable after
removing, reinstall them in the same position as
removed.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta 36-220 and is the answer not in the manual?