ASDA-A2  Chapter 7 Motion Control 
7-26     Revision February, 2017 
7.10.2  Programming the Path in PR Mode 
1)  Sequence command 
 
Path 1: is AUTO and has set DLY 
Path 2: does not set INS 
(DLY starts to count after completing 
the command) 
 
Path 1: speed command and has set 
DLY 
Path 2: position command 
(DLY starts to count after completing   
the    command) 
 
2) Overlap 
 
Path 1: has set OVLP but cannot       
set DLY 
Path 2: does not set INS 
3) Internal Interrupt 
 
Path 1: AUTO and has set DLY  
Path 2: has set INS 
(DLY is effective to the internal 
interrupt) 
It can be used to pre-constitute 
complicated Profile 
4) External Interrupt 
 
Path 1: AUTO or SINGLE  
Regardless the setting of DLY 
Path 2: has set INS 
(DLY is ineffective to the external 
interrupt) 
Profile can be changed from external 
any time