7.2.3 Connecting the Communication Wiring
Multiple inverters could be monitored via RS-485 connection (Figure 5-7), but each
inverter’s ID must be set.
7.2.4 Inverter ID Setting
1. Turn on DC power and wait for the LCD display to be ok, then press “Select” button
until “Inverter ID: XX" is shown in the LCD.
2.
Press and hold both buttons (“Enter” first then “Select”) until entering setting ID screen,
then you could release the both buttons and set ID by pressing “Select” button, press
“Enter” button if the ID is correct (ID = 1 ~ 254).
3. Inverter ID is changed and saved.
7.3 LCD flowchart
Press any button will enter menu page (Figure 7-5), Today Output Energy is home page,
and several item is described in section 7.3.1 ~ 7.3.6.
Make sure the inverter ID is different from each other in the same train.
Single inverter could be monitored RS-485 connection.
NOTE