Chapter 4 Parameters
VFD-EL-W
4-35
01.23
Simple Positioning Stop Frequency 3 Unit: 0.01
Settings 0.00–400.00Hz Default: 20.0
01.24
Simple Positioning Stop Frequency 4 Unit: 0.01
Settings 0.00–400.00Hz Default: 30.00
01.25
Simple Positioning Stop Frequency 5 Unit: 0.01
Settings 0.00–400.00Hz Default: 40.00
01.26
Simple Positioning Stop Frequency 6 Unit: 0.01
Settings 0.00–400.00 Hz Default: 50.00
01.27
Simple Positioning Stop Frequency 7 Unit: 0.01
Settings 0.00–400.00 Hz Default: 60.00
The setting for Pr.01.20–Pr.01.27 must follow the condition below:
Pr.01.20 ≤ Pr.01.21 ≤ Pr.01.22 ≤ Pr.01.23 ≤ Pr.01.24 ≤ Pr.01.25 ≤ Pr.01.26 ≤ Pr.01.27
If any two of the parameters (between Pr.01.20–Pr.01.27) have the same stop frequency, set their Delay Time
of Simple Positioning Stop to the same values.
01.28
Delay Time of Simple Positioning Stop 0 Unit: 0.01
Settings 0.00–600.00 sec. Default: 0.0
01.29
Delay Time of Simple Positioning Stop 1 Unit: 0.01
Settings 0.00–600.00 sec. Default: 0.00
01.30
Delay Time of Simple Positioning Stop 2 Unit: 0.01
Settings 0.00–600.00 sec. Default: 0.00
01.31
Delay Time of Simple Positioning Stop 3 Unit: 0.01
Settings 0.00–600.00 sec. Default: 0.0
01.32
Delay Time of Simple Positioning Stop 4 Unit: 0.01
Settings 0.00–600.00 sec. Default: 0.00
01.33
Delay Time of Simple Positioning Stop 5 Unit: 0.01
Settings 0.00–600.00 sec. Default: 0.00
01.34
Delay Time of Simple Positioning Stop 6 Unit: 0.01
Settings 0.00–600.00 sec. Default: 0.00
01.35
Delay Time of Simple Positioning Stop 7 Unit: 0.01
Settings 0.00–600.00 sec. Default: 0.00
This is valid only when Pr.02.02 motor stop method is set to 4: simple positioning stop.
The settings 0–7 for Pr.01.20–Pr.01.27 must work with the settings 0–7 for Pr.01.28–Pr.01.35 and correspond
to each other. Below is their corresponding.
(Pr.01.20, Pr.01.28)
(Pr.01.21, Pr.01.29)
(Pr.01.22, Pr.01.30)
(Pr.01.23, Pr.01.31)
(Pr.01.24, Pr.01.32)
(Pr.01.25, Pr.01.33)
(Pr.01.26, Pr.01.34)
(Pr.01.27, Pr.01.35)
The function of Pr.01.28–Pr.01.35 is simple positioning. Speed starts to decelerate after the time set at
Pr.01.28–Pr.01.35 elapses. The accuracy of positioning is self-assessed by user.