Chapter 12 Description of Parameter SettingsME300
12.1-12-12
Main Frequency Time Setting
1
st
Speed Time Setting
2
nd
Speed Time Setting
3
rd
Speed Time Setting
4
th
Speed Time Setting
5
th
Speed Time Setting
6
th
Speed Time Setting
7
th
Speed Time Setting
Default: 0
Settings 0–65500 sec.
Pr.12-42 to Pr.12-49 correspond to the operation time for each multi-step speed defined.
The maximum value for these parameters is 65500 sec., and it displays as 65.5.
If it is set to 0 (0 sec.), the corresponding step skips. This is commonly used to reduce number of
program steps.