14 Version 20
1.5.4. Temperature
Temperature and Parameters
LBB Model Number
1-23
1-69
2-12
2-18
2-27
Time to
temperature
(approximate
minutes with no
load)
40°C-
150°C
17
15
15
17
17
40°C-
204°C
31
29
26
33
33
Recovery time with
door open 1 minute
(approximate
minutes with no
load) *
150°C
2
3
3
3
4
204°C
4
6
6
7
8
Temperature
uniformity at:
150°C
+/- 3°C
+/- 3°C
+/- 2°C
+/- 3°C
+/- 3°C
204°C
+/- 4°C
+/- 4°C
+/- 3°C
+/- 4°C
+/- 4°C
Operating range with 20°C
ambient:
35°C- 204°C
40°C-204°C
Control stability
± 0.5 °C
*Recovery time as measured at control thermocouple.
Dampers must be open to operate at the minimum
temperature.
Time to Temperature” and “Temperature Uniformity
values are based on 240V/60 Hz operation, with control
panel located on top. Actual results may vary slightly
depending on unit configuration and operating conditions.
1.5.5. LBB Series Oven Operating Conditions
The LBB Series oven is for indoor use. Table 1 provides the operating conditions.
Table 1. Operating/Environmental Conditions (For indoor use).
Item
Description
Operating Temperature*
18°C to 40°C (64.4°F to 104°F)
Relative Humidity
70% noncondensing
Maximum Altitude
2,000 meters (6,600 feet)
* Fluctuations in temperature can occur at elevated ambient temperature values.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Despatch LBB 2-27 and is the answer not in the manual?

Despatch LBB 2-27 Specifications

General IconGeneral
BrandDespatch
ModelLBB 2-27
CategoryOven
LanguageEnglish

Related product manuals