Page #6 background image
The information contained here are property of DIGITAX Automotive Electronics Italy, and extremely confidential. Any disclosure, copying, distribution to third
party is strictly prohibited.
6
Movement Sensor:
How to Assemble
SENSOR
Screws B
Screws A
Screws B
Clamps
Sheathing
Speedometer
Cable
1) Take out the internal wire
from the sheathing.
2) Shorten the sheating 36
m/m
3) Insert both ends of the
sheathing in the clamps and
tight the 4 screws B
4) Loosen the 4 screws (A)
and insert the internal wire.
Do not tight the 4 screws A*.
* Attention: when you insert the
internal wire, the dummy shaft must
come out and be dispose off.
Shaft
A) Re-assemble the trasmission cable in the car, connecting it
to both the gear box and the odometer.
B) Drive about 100 mts to allow the internal wire to find its
original position.
C) Tight the 4 screws A.
D) Insert the sensor’s prove.
E) Fix the sensor’s cap to end the sensor’s assembling
operation and to have the sensor fully operative.
Electrical Connections
Red Cable = Power Supply
(5 Vcc to 24)
White Cable = Output Signal
(open collector)
Shield = Ground
Screws (A)
Screw B
Screw B
Clamps
36 m/m
Sensore Capsule